![Hamilton Beach HBFDR3206 Instruction Manual Download Page 21](http://html1.mh-extra.com/html/hamilton-beach/hbfdr3206/hbfdr3206_instruction-manual_4437159021.webp)
EN - 15
3. Remove the terminal block screws which are indicated by A and grounding screw
which is indicated by B. Nuetral ground conductor (central terminal) is provided in the
dryer as a closed loop.
4. Remove the neutral ground conductor from central terminal and connect the
neutral wire of the supply cord under the central terminal of the block. Tighten the
screw.
5. Connect the neutral ground conductor under the screw B. Then connect the
remaining supply cord wires under the outer terminals of the block. Tighten all screws.
After every connection is completed, tighten strain relief clamp in order to secure the
supply cord. Finally, cover up the box cover.