Hamilton Beach Commercial HSV1000 Operation Manual Download Page 5

5

Before You Begin

Do not plug in the Immersion Circulator until you have completed the following steps:
1. 

Choose a vessel or container that can hold up to 8 gallons (30 L) and at least 4½ inches (12 cm) or greater in 

depth. Water should never be above MAX fill line or below MIN fill line; add or remove water if necessary. 

The container should be large enough to allow water to circulate between and around sealed food. Water will 

circulate even if base of Stainless Steel Housing is resting on vessel bottom.

2. 

To secure Clamp Assembly to vessel or container, loosen Clamp Knob by turning it counterclockwise. 

3. 

Slide Clamp Assembly of Circulator onto side of container and secure Clamp Assembly by turning Clamp Knob 

clockwise until it clicks; this prevents overtightening. 

4. 

The Circulator can be adjusted up or down by pushing Adjustment Lever towards Circulator.

NOTE:

 The Clamp Assembly Adjustment Lever allows Circulator to be removed from vessel for cooling or 

cleaning without having to remove Clamp Assembly. 

5. 

Fill the vessel with water. Keep in mind that when your food is added, the water level could rise above the MAX 

fill line. Always keep water level between MAX and MIN Fill Lines.

1. 

If necessary, adjust water level, then plug Immersion Circulator into outlet.

NOTE: 

This Circulator has an internal memory feature that allows it to stop and start at same point of operation 

when last unplugged. Always press   (Start/Stop) Button until light is no longer illuminated before unplugging. 

When Circulator is plugged in again, the display will light up, then show current water temperature and previous 

time set.

2. 

Press   (SET) Button to change time and temperature settings. Time or temperature will flash to indicate which 

setting is being adjusted.

3. 

Press   (SET) Button once to select temperature. Temperature will flash, indicating temperature can be 

adjusted. 

4. 

Press 

 or 

 Button to adjust temperature.

5. 

Press   (SET) Button again and time will flash indicating time can be adjusted.

6. 

Press 

 or 

 Button to adjust to desired cooking time. Press   (SET) Button again to save adjusted time.

NOTE:

 If    (SET) Button is pressed with no change to temperature or time, display will stop flashing in 

 

12 seconds.

7. 

Press   (Start/Stop) Button. Water begins heating and temperature display shows current water temperature. 

Circulator beeps when set temperature is reached. 

8. 

For even cooking, add pouches to water, making sure pouches do not touch and water can circulate around 

each. Press   (Start/Stop) Button to start timer countdown.

9. 

Circulator will beep once when timer reaches 0:00 and will continue to maintain set temperature until Start/Stop 

Button is pressed. Press and hold   (Start/Stop) Button until light is no longer illuminated. Unplug. 

2

1

3

4

Operation

w

 

WARNING

 

Electrical Shock Hazard. 

Do not submerge above the 

MAX water level line. If the appliance should become completely submerged, 
unplug —do not reach into water—and allow it to cool before removing it 
from the water.  Allow the appliance to dry out completely before use. 

Summary of Contents for HSV1000

Page 1: ...al Page 2 THERMOSTAT D IMMERSION POUR CUISSON SOUS VIDE Manuel d utilisation Page 8 CIRCULADOR DE INMERSI N SOUS VIDE Manual de Operaci n Pagina 14 READ BEFORE USE LIRE AVANT D UTILISER LEA ANTES DE U...

Page 2: ...top button then unplug from outlet when not in use before putting on or taking off parts and before cleaning To unplug grasp the plug and pull from the outlet Never pull from the power cord 8 Do not o...

Page 3: ...e plug in any way or by using an adapter If the plug does not fit into the outlet have an electrician replace the outlet w WARNING Electrical Shock Hazard Plug into a grounded outlet Do not remove gro...

Page 4: ...MIN Fill Line Pump Outlet Temperature Indicator Illuminates to indicate Celsius or Fahrenheit Start Stop Button Time Display 5 mins 99 hours Temperature Display 41 203 F 5 95 C SET Button Use to set b...

Page 5: ...ged Always press Start Stop Button until light is no longer illuminated before unplugging When Circulator is plugged in again the display will light up then show current water temperature and previous...

Page 6: ...wise until secure repeat with remaining Screw B w WARNING Electrical Shock Hazard Disconnect power before cleaning Do not submerge cord plug or unit in any liquid Screw A Screw B 2 General Cleaning Af...

Page 7: ...rculator Water may not be circulating Call Technical Services H2O shows on display Circulator may not be in water Add Circulator to water and follow instruction in Before You Begin section Water level...

Page 8: ...e arr t et d brancher ensuite de la prise lorsqu il n est pas utilis avant d installer ou d enlever des pi ces et avant de le nettoyer Pour d brancher saisir la fiche et la retirer de la prise Ne pas...

Page 9: ...soit ou en utilisant un adaptateur Si la fiche ne s ins re toujours pas demander un lectricien de remplacer la prise w AVERTISSEMENT Risque de choc lectrique La fiche s ins re dans une prise mise la...

Page 10: ...tie de la pompe Indicateur de temp rature S allume pour indiquer en Celsius ou Fahrenheit Bouton marche arr t Afficheur de la dur e 5 mins 99 heures Affichage de la temp rature 5 95 C 41 203 F Bouton...

Page 11: ...brancher Lorsque le thermostat est branch nouveau l afficheur s illuminera et affichera ensuite la temp rature actuelle de l eau et le r glage pr c dent de la dur e 2 Appuyer sur le bouton SET r glag...

Page 12: ...avant le nettoyage Ne pas immerger le cordon d alimentation la fiche ou l appareil dans tout liquide General Cleaning After Regular Use 1 Essuyer le thermostat d immersion et l assemblage de pince l...

Page 13: ...communiquer avec les services techniques L afficheur indique H2O Le thermostat n est peut tre pas dans l eau Ajouter le thermostat dans l eau et suivre les instructions indiqu es la section Avant de c...

Page 14: ...el aparato presionando el bot narranque paro a continuaci n desench felo del tomacorriente cuando no est en uso antes de poner o quitar piezas y antes de limpiarlo Para desenchufarlo tome el enchufe y...

Page 15: ...e de ninguna manera o usando un adaptador Si el enchufe no entra en el tomacorriente haga que un electricista remplace el tomacorriente w ADVERTENCIA Riesgo de descarga el ctrica Enchufe en un tomacor...

Page 16: ...MIN Salida de la bomba Indicador de temperatura Se ilumina para indicar Celsius o Fahrenheit Bot n arranque paro Visualizaci n de la hora 5 mins 99 horas Pantalla de temperatura 41 203 F 5 95 C Bot n...

Page 17: ...z que se desconect Siempre presione el bot n arranque paro hasta que la luz ya no est encendida antes de desenchufar Cuando el circulador se enchufe nuevamente la pantalla se encender luego mostrar la...

Page 18: ...to de la mordaza Deslice las dos piezas juntas y con un destornillador Phillips gire un tornillo B en el sentido de las agujas del reloj hasta que quede fijo repita con el tornillo restante B Nettoyag...

Page 19: ...ede no estar circulando Llame a Servicios t cnicos H2O se muestra en la pantalla El circulador puede no estar en el agua Agregue el circulador al agua y siga las instrucciones en la secci n Antes de c...

Page 20: ...l ctricas HSV1000 XS01 120 V 60 Hz 1200 W Los modelos inclu dos en el instructivo de Uso y Cuidado pueden ir seguidos o no por un sufijo correspondiente a una o varias letras del alfabeto y sus combin...