6.  In the “The wizard found a driver for the following device:” window, after the “HAMAMATSU 

xxxxx” or “HPK xxxxx”(xxxxx : Product number) driver has been identified and 
“UsbCamIF.inf ” has been confirmed in the driver location, click the “Next >” button. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

7.  After the required files are copied, confirm that the following window is displayed and click 

the “Finish” button. The driver is now installed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Click 

Click 

Summary of Contents for C9266-03

Page 1: ...proper handling and operation that does not comply with the instructions in this manual may result in serious accident including injury or death Keep this instruction manual handy so that you can easi...

Page 2: ...semble or modify any part of this product Malfunctions might otherwise occur b Be careful not to drop bump or apply excessive impacts to this product Drop impacts or bumps may damage the product c Nev...

Page 3: ...and documentation are reserved to us 4 Reproduction Users can reproduce this software for backup purposes in compliance with the terms of any provision of this license 5 Prohibition clause The user c...

Page 4: ...Hardware setup 4 2 3 Installing the driver 5 3 Operation 21 4 Functions 22 5 Specifications 24 5 1 Specifications 24 5 2 Data acquisition timing charts 25 5 3 Pin arrangement 28 5 4 Dimensional outlin...

Page 5: ...with all these functions the C9266 03 C9266 04 still offers compact size light weight and easy use The C9266 03 C9266 04 has five data acquisition modes One is an internal sync mode Internal mode tha...

Page 6: ...are fed to the CCD through this connector Analog video signals from the CCD proportional to X ray intensity levels and synchronized timing signals H CMOS logic level signals are input to this connecto...

Page 7: ...C9266 04 5 Power switch The power switch used to turn the C9266 03 on or off Select how power is supplied by using the switch position as shown in the table below Switch position Description Left Pow...

Page 8: ...re for use with the C9266 03 C9266 04 CCD Data Acquisition Unit C9266 03 C9266 04 Front Panel C9266 03 C9266 04 Rear Panel DC 5 0 V CCD S10810 S10811 USB 2 0 DC Power Supply or AC Adapter Pulse Genera...

Page 9: ...he Camera module to the USB connector of the PC and ii Connecting the module or the Camera module to an external power source if any 2 3 1 Compliant operating systems This driver is compliant with the...

Page 10: ...ating from Microsoft s home page Hereafter abbreviated as HP After the Service Pack is installed carry out Windows Update Regarding the procedure and details for Service Pack please refer to Microsoft...

Page 11: ...at HAMAMATSU xxxxx or HPK xxxxx xxxxx Product number is displayed click the Search for a suitable driver for my device recommend radio button to select it and then click the Next button 5 In the follo...

Page 12: ...er the HAMAMATSU xxxxx or HPK xxxxx xxxxx Product number driver has been identified and UsbCamIF inf has been confirmed in the driver location click the Next button 7 After the required files are copi...

Page 13: ...installed right click on My Computer and select Properties The System Properties window will be displayed In this window click the Hardware tab and then click the Device Manager button Check whether...

Page 14: ...Switch on the PC When the USB camera module is connected to an external power source switch it on after the PC has been turned on 3 Check that HAMAMATSU xxxxx or HPK xxxxx xxxxx Product number is dis...

Page 15: ...e best driver in these locations radio button and the Search removable media floppy CD ROM check box to select it and click the Next button 5 After the required files are copied confirm that the follo...

Page 16: ...installed right click on My Computer and select Properties The System Properties window will be displayed In this window click the Hardware tab and then click the Device Manager button Check whether...

Page 17: ...e PC When the USB camera module is connected to an external power source switch it on after the PC has been turned on 2 Insert the CD ROM that is provided Right click on My Computer and select Propert...

Page 18: ...cquisition Module C9266 03 C9266 04 14 Right click on HAMAMATSU USB Camera Module and select Properties Click the Driver tab and select Update Driver 3 Click the Next button in the following window Cl...

Page 19: ...known drivers for this device so that I can choose a specific driver radio button to select it and then click the Next button 5 In the following window select HAMAMATSU USB Camera Module from the Mod...

Page 20: ...66 03 C9266 04 16 6 Confirm that the following window is displayed and then click the Next button 7 After the following window is displayed click Browse and specify the path as shown below and click O...

Page 21: ...the Finish button The driver is now upgraded 9 After the driver is installed right click on My Computers and select Properties The System Properties window will be displayed In this window click the...

Page 22: ...is connected to an external power source switch it on after the PC has been turned on 2 Right click on My Computer and select Properties The System Properties window will be displayed In this window c...

Page 23: ...erting the CD ROM that is provided click the Install the software automatically Recommended radio button to select it and then select the Next button 4 After the required files are copied confirm that...

Page 24: ...installed right click on My Computer and select Properties The System Properties window will be displayed In this window click the Hardware tab and then click the Device Manager button Check whether...

Page 25: ...4 comes with dedicated application software C9266DCamAPL Use this software for control of C9266 03 C9266 04 and data acquisition For information on how to use the C9266DCamAPL software refer to the se...

Page 26: ...a trigger signal from the application software The other mode is External Trigger mode which acquires data with a trigger signal from an external device The External Trigger mode is further subdivided...

Page 27: ...66 03 C9266 04 hardware exposure time for CCD in steps from 1 to 65 535 mSec But in the case of EXT EDGE1 data acquisition mode it ranges from 41 to 65 535 mSec If data acquisition mode is Internal mo...

Page 28: ...Min Scanning rate 1MHz Frame readout time 1 62 sec 2 18 sec Data transfer time 1 62 sec 2 17 sec Total cycle time 1 62 sec 2 18 sec AD conversion resolution 12 bits 4095ADU Conversion gain 48 8e ADU R...

Page 29: ...r Time Data Acqusition Time Exposure Time Exposure Time Trigger In Softw are Exposure Signal P1V P2V P1H P2H AD Conversion Data Transfer USB2 0 Data Transfer USB1 1 Data Transfer Time Data Transfer Ti...

Page 30: ...a Transfer Time Data Acquisition Time Dummy Scan Dummy Scan Exposure Time Exposure Time External Trigger In fromBNC Exposure Signal P1V P2V P1H P2H AD Conversion Data Transfer USB2 0 Data Transfer USB...

Page 31: ...NC connector this mode is not usable in the C9266 04 Data Transfer Time Data Transfer Time Data Transfer Time Data Transfer Time Data Acqusition Time Dummy Scan Dummy Scan Exposure Time Exposure Time...

Page 32: ...3V 20 P2H 0V 12V 3 SG 0V 12V 21 NC 4 TRIGGER 8V 13V 22 P1H 0V 12V 5 RG 0V 12V 23 NC 6 NC 24 GND 8V 7 OG 11V 25 NC 8 NC 26 RD 20V 9 RD 20V 27 NC 10 NC 28 OD 23V 11 OD 23V 29 NC 12 NC 30 GND 8V 13 OUT 3...

Page 33: ...CCD Data Acquisition Module C9266 03 C9266 04 29 5 4 Dimensional outlines 1 C9266 03 dimensional outlines...

Page 34: ...CCD Data Acquisition Module C9266 03 C9266 04 30 2 C9266 04 dimensional outlines...

Page 35: ...the product or you suspect possible trouble please check it again This is important in order to clarify the failure symptoms and avoid making faulty judgments 5 If a failure is found in the product or...

Page 36: ...CCD Data Acquisition Module C9266 03 C9266 04 32 7 Document History Date Document Revision Contens 07 Aug 2009 1 00 First edition...

Page 37: ...u Hamamatsu City Shizuoka Pref 435 8558 Japan Phone 81 53 434 3311 Fax 81 53 434 5184 Document Number K46 B60041 Document Revision 1 00 01 Jun 2009 Information in this document is subject to change wi...