background image

 

Things to avoid in installation 

Avoid installing Thingsee products near the following 

 

Thick concrete structures or thick fire doors 

 

Thick electrical wires 

 

Electrical transformers 

 

Escalators 

 

Nearby heating or cooling devices and/or vents 

 

Direct sun light 

 

Nearby halogen lamps, fluorescent lamps or similar lamps with hot 
surface 

 

Nearby radio equipment like WiFi routers or any other similar high power 
RF transmitters. 

 

Avoid installing the sensor in close proximity to a spot where there’s 

people presence constantly, such as right next to workstations. 

 

Installation 

Open the box and follow the instructions of this user and installation guide. 
Take product from the box and open it with the opening key. Select a place 
where to install Thingsee AIR (see 

‘Things to avoid in installation’ before) 

-

recommended height 1,4 m 

 1,8 m. 

 

Summary of Contents for Thingsee AIR TSAR01

Page 1: ...powered wireless IoT sensor for your indoor air quality monitoring Together with CO2 TVOC temperature barometric pressure and humidity sensors it is a perfect device to provide extensive overlook to b...

Page 2: ...rops at least once per day Possibility for manual baseline calibration CO sensor is a nondispersive infrared sensor NDIR TVOC Total volatile organic compounds Resolution is 1ppb at range 0ppb 2008ppb...

Page 3: ...95mm Height 26 88mm Length 92 95mm Weight 100 g Environment info Environment Operating temperature 5 C 50 C Operating humidity 0 85 RH non condensing Storage temperature 5 C 25 C Storage humidity 45 8...

Page 4: ...ure is 400 ppm There must be free of people moments with full ventilation in the space so the device works best in locations where there are no people 24h Note Thingsee AIR requires free of people mom...

Page 5: ...ps with hot surface Nearby radio equipment like WiFi routers or any other similar high power RF transmitters Avoid installing the sensor in close proximity to a spot where there s people presence cons...

Page 6: ...he next sensor or gateway This is to ensure full coverage mesh network between the sensors and the gateway Detection Capability CO2measurement range 400 5 000 ppm extended range up to 10 000 ppm Accur...

Page 7: ...e change 0 5 C Humidity when absolute change 2 Barometric pressure when absolute change 20 hPa Ambient light when absolute change 10000 Time based reporting Reports all measurement values every 1 hour...

Page 8: ...radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance of 5 mm between the radiator and your body This transmitter m...

Page 9: ...taking them to appropriate collection point When changing batteries replace both of them at the same time using identical brand and type Do not swallow batteries Do not throw batteries into water or f...

Page 10: ...f life The purpose of this Directive is as a first priority the prevention of WEEE and in addition to promote the reuse recycling and other forms of recovery of such wastes so as to reduce disposal Th...