background image

                                                                 

                 

                   

 

 

28

equipment is defective in material or workmanship, i.e. contains a defect arising out of 

the manufacture of the equipment and not a defect caused by other circumstances, 

including, but not limited to accident, misuse, unforeseeable use, neglect, alteration, 

improper installation, improper adjustment, improper repair, or improper testing, Hal 

Technology shall, at its option, repair or replace the equipment, shipment to Buyer 

prepaid. Hal Technology shall have reasonable time to make such repairs or to replace 

such equipment. Any repair or replacement of equipment shall not extend the period of 

warranty. If the Instrument is modified or in any way altered without the explicit written 

consent of Hal Technology then the warranty is null and void.

 

This warranty is limited to 

a period of one year, except as noted below, without regard to whether any claimed 

defects were discoverable or latent on the date of shipment.

 

B. If Buyer shall fail to pay when due any portion of the purchase price or any other 

payment required from Buyer to Hal Technology under this contract or otherwise, all 

warranties and remedies granted under this Section may, at Hal Technology’s option, 

be terminated. 

C. Warranty repairs shall be completed at a Hal Technology authorized service location, 

by an authorized service technician, or on site at buyer’s facility by a Hal Technology 

authorized employee. Buyer pays shipping costs to factory; seller will pay standard 

return shipping costs during the warranty period. Buyer may select a faster method of 

shipment at their own expense. 

 

Warranty of Repairs after Initial One (1) Year Warranty 

A. Upon expiration of the initial one-year warranty, all parts and repairs completed by an 

authorized Hal Technology repair technician are subject to a six (6) month warranty. 

B. Other than the above, Hal Technology makes no warranty of any kind, expressed or 

implied, except that the products manufactured and sold by Hal Technology shall be 

free from defects in materials and workmanship and shall conform to Hal Technology’s 

specifications; Buyer assumes all risk and liability resulting from use of the products 

whether used singly or in combination with other products. If instrument is modified or in 

any way altered without the explicit written consent of Hal Technology, then the 

warranty is null and void. 

C. Warranty repairs shall be completed at a Hal Technology authorized service location, 

Summary of Contents for HAL-HPC300

Page 1: ...HAL HPC300 Handheld Particle Counter Operational Manual 625 E Carroll Avenue Glendora CA 91741 USA Phone 510 579 8540 Fax 626 963 7302 Info haltechnologies com http haltechnologies com...

Page 2: ...This Page intentionally left as blank...

Page 3: ...ent Bring you attention about the features of the instrument Unpacking and Inspection Inspect the receiving package and notify the shipper immediately if there appears to be susceptible damage during...

Page 4: ...e specified limits Technical Support and Warrantee Within a year from the date purchased the manufacturer will provide free technical support and software upgrade For additional help please contact in...

Page 5: ...1 2 Features 7 II Basic Operation 9 2 1 Handheld Unit 9 2 2 Control Panel 11 2 3 Operational Windows 11 2 3 1 Startup Page 11 2 3 2 Measuring Window 12 2 3 3 Browsing Window 16 2 3 4 Setting Window 18...

Page 6: ...ing data real time printing software upgrading and battery charging etc In addition to USB and RS232 interfaces the RJ45 interface allows users to conduct the remote sampling away from the sampling lo...

Page 7: ...mpling Average of multiple times of measurements External digital temperature and humility sensors to assure accurate measurement Up to 26 location labels of measurements No less than 6 hours of conti...

Page 8: ...w calibration 5 insufficient battery Communication Speed USB 12Mbps RJ45 100Mbps RS 232 9600bps Power Li ion polymer Battery 7 4V 2800mAH or AC adapter AC input 100 240V DC output 9V 1 5A Max Operatin...

Page 9: ...II Basic Operation 2 1 Handheld Unit Figure 1 Front View of the Handheld Set Temperature Relative Humidity Probe Interface Power Switch Back Lit LCD Display Air Intake Control Panel...

Page 10: ...to the USB interface of a computer COM port Connect to the printer or serial port of a computer POWER An AC adapter plug in port Thread bore is used for a tripod to minimize a human affect on the ste...

Page 11: ...r about 2 seconds to turn off the instrument After about 8 minutes standby or no operation the instrument will shut off automatically to save the power RUN STOP Start or stop a measurement operation M...

Page 12: ...t and conditions according to the unit setting One may wish to change the setting before the measurement run by pressing up or down arrow to enter into the Setup Window page An example of the Measurin...

Page 13: ...d The sound can only be quieted by turning off the instrument Flashing of the sensor error indicates that the sensor is dirty A zero count filter attached to the air sampling intake may clean the sens...

Page 14: ...in a unit volume under the accumulative situation The unit volume may be set Counts per Liter Counts per Cubic Meter Counts Cu M or Counts per Cubic Foot Counts Cu Ft Sample Time SampTime Sample time...

Page 15: ...date and time is always displayed in the format of month day year and hour minute second respectively Date and time can be changed in the Setting window If the instrument is set as the manual saving m...

Page 16: ...he user to browse print or delete historic data In the Browsing window press ENTER keypad to enter into the last saved data record Then use the arrow keypad to scroll through the stored data Use keypa...

Page 17: ...a CUMU Displays the mode that data was saved in CUMU Record Format as number of saved data total number of stored Data e g 0015 0110 SampTime Displays the length of sampling time of a saved data Tempe...

Page 18: ...ve up or down for highlighted selection Press BACK keypad to return to the previous Browsing window Press ENTER keypad to confirm the print or delete selection Toggle between Yes and No selection with...

Page 19: ...o confirm the parameter s setting Press BACK keypad to back to the previous window Figure 13 Setting Window page Sizes The user may change the size of the middle channel selected from 0 5 m 0 7 m 1 0...

Page 20: ...pressing the RUN keypad and the beginning of the actual sample measurement The user also has the option of setting a time interval between two consecutive sample runs when the Count Mode see below is...

Page 21: ...e touched The factory setting for this function is set to Off BackLight The back light of LCD display may be configured to stay on for the following lengths of time On Off 5 seconds 15 seconds 30 seco...

Page 22: ...obe into water Zero Count Filter and Purge Test The instrument must be periodically cleaned using the purge filter Following are instructions to purge the unit 1 Unscrew the iso kinetic probe and atta...

Page 23: ...on the setup executable provided on the CD ROM and be sure that your com settings are set to either USB Downloaded data could be managed deleted and saved as a Microsoft Excel file format Use the data...

Page 24: ...Functional LED Function Push Button Power LED Power Push Button AC Adaptor Socket Beeper Functional LED Function Push Button Power LED Power Push Button AC Adaptor Socket Beeper Paper Loading Cover P...

Page 25: ...ning Power LED turns red when the battery below the normal usage level Auto sleep mode The printer goes to sleep mode after 10 seconds if no printing command is received The printer will go to working...

Page 26: ...reen Waiting for recediving data and ready to print Flash green Paper feeding Functional LED Flash red No paper Sound high and low Printer turn on Sound low and high Printer turn off Sound high three...

Page 27: ...ration in an un specified environmental condition Abnormal operation due to instrument needing calibration Limitation of Warranty A Hal Technology warrants that all equipment shall be free from defect...

Page 28: ...medies granted under this Section may at Hal Technology s option be terminated C Warranty repairs shall be completed at a Hal Technology authorized service location by an authorized service technician...

Page 29: ...eturn shipping costs during the warranty period Buyers may select a faster method of shipment at their own expense Contact HAL TECHNOLOGY LLC 625 E Carroll Avenue Glendora CA 91741 USA Phone 510 579 8...

Page 30: ...User Registration Form Company _____ Contact Person ______________ Address ______ ______ __ City ____State Province Country _____ Postal Code _________ Phone ________________ Fax __________________ E...

Reviews: