background image

 

Operating Instructions PS27 

 

Contents 

 

1.

 

Safety Instructions ................................................................................................ 5

 

1.1 Use for Intended Purpose Only ........................................................................... 5

 

1.2 Transport, Installation, Connection and Startup .................................................. 5

 

1.3 Malfunctions, Maintenance, Repairs, Disposal .................................................... 5

 

1.4 Symbols .............................................................................................................. 6

 

2.

 

Description of the pressure transmitter .............................................................. 6

 

3.

 

Startup ................................................................................................................... 6

 

3.1 Functional Description ........................................................................................ 6

 

3.2 Connections for Four-Wire version (standard) in the device: ............................... 7

 

3.3 Connections for Two-Wire System (Option): ....................................................... 8

 

3.4 Connections M12-plug ........................................................................................ 8

 

4.

 

Resetting Offset .................................................................................................... 8

 

5.

 

Configuring the Output Signal ............................................................................. 9

 

6.

 

Setting the Measuring Range (Optional) ............................................................. 9

 

7.

 

Display (Option) .................................................................................................. 10

 

8.

 

Setting the Relay Operating Point (Option) ....................................................... 10

 

9.

 

In case of Malfunctions ...................................................................................... 10

 

10.

 

Specifications ..................................................................................................... 11

 

11.

 

Dimensional Drawing ......................................................................................... 12

 

12.

 

Certificates of Conformity .................................................................................. 13

 

 

 

 

Summary of Contents for PS27

Page 1: ...ential Pressure Transmitter PS27 halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Germany Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E mail info halstrup walcher com Internet www hal...

Page 2: ...Code 2022 The manufacturer owns the copyright to this instruction manual It contains technical data instructions and drawings detailing the device s features and how to use them It must not be copied...

Page 3: ...must be given to these operating instructions and in particular to the associated safety instructions Do contact the manufacturer should you not understand all the sections Be heedful of the operatin...

Page 4: ...er 6 3 Startup 6 3 1 Functional Description 6 3 2 Connections for Four Wire version standard in the device 7 3 3 Connections for Two Wire System Option 8 3 4 Connections M12 plug 8 4 Resetting Offset...

Page 5: ...ator Only instructed persons as assigned by the plant operator are to operate the transmitter Do not perform any functional test involving compressed or breathable air This would otherwise damage thos...

Page 6: ...ional Description PS27 pressure transmitters are of the precision type and despite their sturdiness they should still be treated with care Installation right next to heat and radiation sources e g rad...

Page 7: ...gram on the appliance cover circuit board mount ST4 Pin Connection name Meaning 1 24V Power supply input 24VAC DC 2 GND Ground for power supply 3 OUT Voltage or current output 4 GND Ground for output...

Page 8: ...ed via the input assigned for this purpose The user must ensure that the appliance is not subjected to any pressure during the calibration process as this might lead to a wrong offset value which in t...

Page 9: ...ching of 4 measuring ranges into the appliance has been undertaken by the manufacturer The switches 1 and 2 of SW can be used to select the measuring range in question before the transmitter is switch...

Page 10: ...sor s output so that any adjusted time delay will also cause a delay in relay triggering 9 In case of Malfunctions Fault description Possible cause Corrective action No output signal Supply voltage is...

Page 11: ...o Fitting 4 or 6mm Output signals 0 2 10 V RL 50 kOhm 0 4 20 mA RL 500Ohm 4 20 mA two wire 17 32 V RL 500Ohm Switching contact optional max 230 VAC 6 A min 500 mW Display optional 3 digit LCD Overpres...

Page 12: ...PS27 12 11 Dimensional Drawing For more information on our measurement technology products please visit our homepage at www halstrup walcher de en products measurement technology 7100 004354L_PS27 doc...

Page 13: ...Operating Instructions PS27 13 12 Certificates of Conformity...

Page 14: ...Operating Instructions PS27 14...

Page 15: ...Operating Instructions PS27 15 Notes...