GAS CONTROL VALVE
INCLUDING AIR INLET COWL
9.3
Refer to Figures 35, 36 & 37
a)
Ensure supply voltage is isolated, and that the gas supply is isolated.
b)
Remove the gas control valve, fan & burner assembly; refer to
section 6.2.
c)
Unscrew four screws holding the gas feed pipe, and remove gas feed
pipe, refer to Figure 35.
d)
Unscrew three torx screws (T-20), and remove gas control valve,
refer to Figure 36.
e)
Unclip the top section of the black plastic air inlet cowl from the fan
assembly, and remove white plastic insert, clean or replace as
necessary, refer to Figure 37.
f)
Refit or replace the top section of the black plastic air inlet cowl,
ensuring that it is clipped into place and that the holes in the white
plastic insert are aligned with the fixing holes.
g)
Attach and secure the gas feed pipe to the replacement gas valve,
using a new gasket.
h)
Attach and secure the replacement gas control valve to the fan
assembly.
i)
Re-assemble in reverse order; ensure that all joints and seals are
correctly re-fitted.
Note:
The gas control valve is factory set and sealed and is not
adjustable. If the gas control valve is changed, then when the appliance
is running, the flue gas CO
2
should be measured, refer to section 6.1,
and compared to the values stated in Performance Data, section 2.2. If
the measured value does not correspond to the Performance Data, then
follow section 9.3.1 below or contact: Halstead Glen Dimplex service
helpline Tel: 0844 371 1111.
COMBUSTION CHECK SET-UP
9.3.1
If a new gas valve is fitted or the existing gas valve is not within the
quoted CO
2
values it must be adjusted to operate within the quoted CO
2
values (see Combustion set-up table on the following page).
35
GAS FEED PIPE
37
AIR INLET COWL
36
GAS CONTROL VALVE
4 SCREWS
3 TORX
SCREWS
SWIRL PLATE
AIR INLET COWL TOP
AIR INLET COWL BOTTOM
31
GAS VALVE REPLACEMENT INSTRUCTIONS
The Eden VBX 18 and 30 are category II
2H3P
appliances.
The appliances are supplied for use on Natural Gas (G20) at a supply
pressure of 20 mbar or Propane (G31) at a supply pressure of 37 mbar
but can be converted from NG to Propane or vice versa, using specific
conversion kits. They are certified to comply with the requirements of
EN 483 for use in GB and IE only.
It is the law that all gas appliances are installed and
maintained by a competent person such as a Corgi
registered installer, in accordance with the rules in force.
It is in your own interest, and that of safety, to ensure that
the law is complied with. Failure to do so could lead to
prosecution.
The following instructions are intended for guidance and
in no way override any Statutory Requirements.
a)
The combustion values at minimum gas rate and maximum gas rate
must be checked using a suitably calibrated Flue Gas analyser.
Compliance with BS7967-2, BS7967-3 and BS7967-4 is required.
b)
Do not attempt to adjust the gas valve unless you have a suitable
Flue Gas analyser that is checked and within calibration.
Compliance with BS7967-2, BS7967-3 and BS7967-4 is required.
!