background image

98064C (9/04)

WC8AEEQ*1F

PAGE 2

FIG. 2

E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.

ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR

F = POWER CORD 1-1/2FEET (457mm) LONG

CABLE ELÉCTRICO DE 1½ PIE, 457 mm DE LARGO CORDON D’ALIMENTATION 1-1/2' (457mm)

G = ALT. ELECTRICAL OUTLET LOCATION

UBICACIÓN ALT. DE LA TOMA DE ELECTRICIDAD EMPLACEMENT ALTERNATIF DE LA PRISE DE COURANT

H = THIS BOLT HOLE MUST BE USED FOR FASTENING UNIT TO WALL.

ESTE AGUJERO DE TUERCA DEBERÁ SER USADO PARA ASEGURAR LA UNIDAD A LA PARED. ON DOIT UTILISER CE TROU DE BOULON POUR INSTALLER L’APPAREIL AU MUR.

J = ORIFICE HEIGHT 1-1/4" (32mm) ABOVE RIM

ALTURA DEL ORIFICIO 1-1/4" (32mm) SOBRE LA CORONA HAUTEUR DE L'ORIFICE 1-1/4" (32mm) AUDESSUS DU REBORD

LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38m

m

) O

U

T

FROM WALL SHUT OFF BY OTHERS

 SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1- 1/2" (38m

m

) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.

        EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 m

m

) D.E.

CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38m

m

) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.

B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D.  DRAIN

 UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO. EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.

C = 1-1/4 TRAP NOT FURNISHED**

PURGADOR DE 1¼ NO PROPORCIONADO** SIPHON 1-1/4 NON FOURNI**

D = ELECTRICAL OUTLET LOCATION

UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT

Summary of Contents for WC8AEEQ 1F Series

Page 1: ...PAGE 1 Halsey Taylor Owners Manual USES HFC 134A REFRIGERANT FIG 1 42 30 25 43 26 27 39 40 41 45 49 48 38 46 47 23 19 49 28 20 21 22 24 29 47 31 32 33 18 35 36 37 44 See Fig 3 on Page 3 For Electric Eye Mechanism 50 51 34 52 ...

Page 2: ... HEIGHT 1 1 4 32mm ABOVE RIM ALTURA DEL ORIFICIO 1 1 4 32mm SOBRE LA CORONA HAUTEUR DE L ORIFICE 1 1 4 32mm AUDESSUS DU REBORD LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE ...

Page 3: ...anel and secure by retightening four 4 screws ELECTRIC EYE MECHANISM ITEM NO PART NO Panel Bottom Dispenser Bracket Valve Mounting Sensor Clear 115v 230v Solenoid Valve 115v Solenoid Valve 230v Panel Right Side Panel Left Side Panel Front Elbow 1 4 Stem x 1 4 O D Fitting 1 4 NPTF x 1 4 O D Nut Regulator Screw 6 32 x 1 2 Lg PHMS Screw 10 x 1 2 Lg PHSM Hex Nut Screw 8 x 5 8 Lg Torx Slotted Regulator...

Page 4: ...unting Frame Back Bottom Nipple Bubbler Poly Tubing Cut To Length 31483C 27095C 30664C 70018C 31490C 70009C 56237C 70142C 51544C 100322740560 66743C 66703C 26680C 22708C 50144C 70184C 70150C 36094C 36158C 35768C 35959C 66576C 40572C 40575C 50074C 26664C 70208C 31513C 66534C 55996C 27093C 27094C 27096C 27097C 56159C 56092C DESCRIPTION INCLUDES RELAY OVERLOAD IF UNDER WARRANTY REPLACE WITH SAME COMP...