2000000501 (Rev. B - 04/23)
HTHBSM-1A, HTHBSM-2A, HTHBSMWF-1A, HTHBSMWF-2A
Page 4
Plumbing Connections
• Ensure lines and ports remain clean and free of contaminants during assembly.
• Purge each component if necessary.
• To ensure quick-connect connections seal properly, follow instructions per Fig. 2, Page 2.
Connect Electrical Power:
1.
For 120V Models:
Plug Power Cord into wall outlet.
1.1.
For 220V Models:
Thread one end of Power Cord Plug through Bottom Cover and into Power inlet of Bottle Filler,
then plug other end of power cord into wall outlet. (See Fig. 4, Page 7.)
2.
Confirm unit is on:
2.1. Filtered Units
: Both the Filter Status Green LED and the Bottle Counter LCD on the Nameplate are illuminated.
2.2. Non-Filtered Units
: The Bottle Counter LCD on the Nameplate is illuminated.
3.
Ensure water dispenses:
Activate unit by placing cup, hand or an opaque object in front of Sensor Lens and water
should flow. It is normal for the water stream to sputter with air when the unit is new or a new filter cartridge is installed.
4.
Ensure a steady water flow is obtained:
Activate unit per above and hold until all air entrapped in lines and filter is
purged. Since unit only dispenses water for 20 seconds per activation, multiple activations may be required.
5.
Inspect for leaks
and if any found, unplug unit and correct before continuing.
6.
If setting up the Control Board for the first time,
go to Setting the Control Board (below) before continuing.
7.
For 220V Models:
Place Cable Clamp (supplied) on Power Cord (See Fig. 4, Page 7) allowing sufficient slack for
installing and removing Bottom Cover with cord plugged in and secure Clamp with Screw (supplied).
8.
Place Bottom Cover in position
on underside of unit with long tab against wall and slide up into Back Panel
opening. Secure with two supplied Allen head screws using a 5/32" hex-wrench (not supplied).
9.
For 120V Models:
For a clean appearance, gather and loop any extra Power Cord and secure to the underside of
bottom Cover with supplied adhesive backed clip.
Instruction for Use
1.
To activate water flow,
position mouth of water bottle or container under Dispensing Nozzle and in a continuous motion,
swing and hold container in front of Sensor Lens. Hold until container is filled to level desired.
2.
To stop water flow,
pull container away from Sensor Lens
.
1.
Connect water supply line to unit:
1.1. Filtered Units
: Connect the 3/8" O.D. copper tube (supplied factory attached on the Filter Head inlet port) to the
3/8" Compression end of Service Stop Valve.
1.2.
Non-filtered Units
: Connect the 3/8"O.D. poly tube with Insulation to the 3/8" Compression end of Service Stop Valve.
2.
Connect water supply line from Filter:
2.1. Filtered Units
: Connect the quick-connect Reducing Union Adapter Fitting, located at end of 3/8"O.D. poly tube with
Insulation, to the ¼” O.D. poly tube (supplied factory attached on the Filter Head outlet port).
2.2.
Non-filtered Units
: No connections necessary.
3.
Connect the 1-1/4"O.D. Drain Tray Outlet
to the in-wall Drain Line using a Slip Joint Drain Union or compression
clamp (not supplied). Tighten all connections water tight.
4.
Install new Filter Cartridge
by removing its protective cap, inserting into Filter Head and rotating Filter Cartridge
clockwise until it bottoms-out into Filter Head.
5.
Turn water supply on,
inspect for leaks and correct any leaks before continuing.
Connect Plumbing Lines
Changing the Filter
1.
Remove the Bottom Cover of the Bottle Filler
by removing the two (2) screws.
2.
Remove filter from head
by rotating filter counterclockwise.
3.
Remove new filter from carton,
remove protective cap; cap may be placed on an old filter to reduce the chance of the
water spilling from filter housing.
4.
Attach filter to filter head
by firmly inserting into head and rotating filter clockwise.
5.
Activate sensor on Bottle Filler
until approximately 1 gallon of water is dispensed. This flushing procedure purges air
and fine carbon particles from the filter.