Plumbing Connections

•  Ensure lines and ports remain clean and free of contaminants during assembly.
•  Purge each component if necessary.
•  To ensure quick-connect connections seal properly, follow instructions per Fig. 2, Page 2.

Connect Electrical Power:

1.     

For 120V Models: 

Plug Power Cord into wall outlet.

1.1.  

For 220V Models:

 Thread one end of Power Cord Plug through Bottom Cover and into Power inlet of Bottle Filler,  

 

 then plug other end of power cord into wall outlet. (See Fig. 4, Page 7.)

2.     

Confirm unit is on: 

2.1.  Filtered Units

: Both the Filter Status Green LED and the Bottle Counter LCD on the Nameplate are illuminated.

2.2.  Non-Filtered Units

: The Bottle Counter LCD on the Nameplate is illuminated.

3.   

Ensure water dispenses: 

Activate unit by placing cup, hand or an opaque object in front of Sensor Lens and water

 

should flow. It is normal for the water stream to sputter with air when the unit is new or a new filter cartridge is installed.

4.   

Ensure a steady water flow is obtained: 

Activate unit per above and hold until all air entrapped in lines and filter is

 

purged. Since unit only dispenses water for 20 seconds per activation, multiple activations may be required.

5.   

Inspect for leaks

 and if any found, unplug unit and correct before continuing. 

6.   

If setting up the Control Board for the first time,

 go to Setting the Control Board (below) before continuing.

7.   

For 220V Models:

 Place Cable Clamp (supplied) on Power Cord (See Fig. 4, Page 7) allowing sufficient slack for 

installing and removing Bottom Cover with cord plugged in and secure Clamp with Screw (supplied).

8.   

Place Bottom Cover in position

 on underside of unit with long tab against wall and slide up into Back Panel

 

opening.  Secure with two supplied Allen head screws using a 5/32" hex-wrench (not supplied).

9.   

For 120V Models:

 For a clean appearance, gather and loop any extra Power Cord and secure to the underside of

 

bottom Cover with supplied adhesive backed clip.

Instruction for Use

1.  

To activate water flow,

 position mouth of water bottle or container under Dispensing Nozzle and in a continuous motion,

  swing and hold container in front of Sensor Lens.  Hold until container is filled to level desired.

2. 

 To stop water flow,

 pull container away from Sensor Lens

.

1.

   

Connect water supply line to unit: 

1.1.   Filtered Units

: Connect the 3/8" O.D. copper tube (supplied factory attached on the Filter Head inlet port) to the

 

 3/8" Compression end of Service Stop Valve. 

1.2.   

Non-filtered Units

: Connect the 3/8"O.D. poly tube with Insulation to the 3/8" Compression end of Service Stop Valve.

2.

   

Connect water supply line from Filter: 

2.1.  Filtered Units

: Connect the quick-connect Reducing Union Adapter Fitting, located at end of 3/8"O.D. poly tube with

 

Insulation, to the ¼” O.D. poly tube (supplied factory attached on the Filter Head outlet port). 

2.2.  

Non-filtered Units

: No connections necessary.

3.    

Connect the 1-1/4"O.D. Drain Tray Outlet 

to the in-wall Drain Line using a Slip Joint Drain Union or compression

 

 clamp (not supplied). Tighten all connections water tight. 

4.    

Install new Filter Cartridge

 by removing its protective cap, inserting into Filter Head and rotating Filter Cartridge

 

clockwise until it bottoms-out into Filter Head. 

5.    

Turn water supply on,

 inspect for leaks and correct any leaks before continuing. 

Connect Plumbing Lines

Changing the Filter

1. 

Remove the Bottom Cover of the Bottle Filler

 by removing the two (2) screws.

2. 

Remove filter from head 

by rotating filter counterclockwise. 

3. 

Remove new filter from carton,

 remove protective cap; cap may be placed on an old filter to reduce the chance of the 

  water spilling from filter housing.

4. 

Attach filter to filter head

 by firmly inserting into head and rotating filter clockwise.

5. 

Activate sensor on Bottle Filler

 until approximately 1 gallon of water is dispensed. This flushing procedure purges air

  and fine carbon particles from the filter.

Summary of Contents for HydroBoost HTHBSM-1A

Page 1: ...n of connecting this product to supply line pressure lower than 20 PSI or higher than 105 PSI is not covered by warranty IMPORTANT THIS IS AN INDOOR APPLICATION ONLY ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL TOOLS ITEMS REQUIRED BUT NOT SUPPLIED SERVICE STOP VALVE WITH 3 8 COMPRESSION OUTLET FASTENERS FOR WALL TYPE 8 REQ D SLIP JOINT DRAIN UNION OR COMPRESSION CLAMP 5 32 HEX W...

Page 2: ... LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D MAXIMUM PIPE SIZE C ELECTRICAL OUTLET THREE 3 CONDUCTOR GROUNDED LOCATE WITHIN SAFE REACH OF POWERCORD D 7 16 X 3 4 OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL FIG 2 B C A SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH I...

Page 3: ...Cover from Bottle Filler by removing two 2 screws from bottom of unit Use a 5 32 hex wrench not supplied Remove and place aside new Filter Cartridge shipped inside Bottle Filler 2 Remove Back Panel from Bottle Filler by removing two 2 screws from top of unit that secures the Top Cover 3 Fasten Back Panel to structurally secure wall thru eight 8 7 16 obround holes with fasteners appropriate for wal...

Page 4: ...a clean appearance gather and loop any extra Power Cord and secure to the underside of bottom Cover with supplied adhesive backed clip Instruction for Use 1 To activate water flow position mouth of water bottle or container under Dispensing Nozzle and in a continuous motion swing and hold container in front of Sensor Lens Hold until container is filled to level desired 2 To stop water flow pull co...

Page 5: ...allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter S...

Page 6: ...e display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display sho...

Page 7: ..._12PK 98543C 98544C 2000000503 98546C 98549C 98631C 2000000502 Filter WaterSentry Plus 12Pack Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V WATERSENTRY PLUS FILTER PARTS LIST See Fig 3 ITEM NO PART NO DESCRIPTION 1 2 3 55898C 1000005553 70792C Filter Assy 3000 G...

Reviews: