background image

2000000501 (Rev. B - 04/23)

HTHBSM-1A,  HTHBSM-2A,  HTHBSMWF-1A,  HTHBSMWF-2A

Page 3

INSTALLATION INSTRUCTIONS

NAMEPLATE

ALCOVE

DRAIN TRAY

TOP COVER

SENSOR LENS

FRONT VIEW

REAR VIEW

REAR CROSS MEMBER 

(ON OUTER WRAPPER)

BOTTOM COVER

OUTER WRAPPER

FILTER

Pre-Installation (reference Rough-In, Fig. 1, Page 2)

1.  

 Ensure Wall is structurally sound

 to bear the loads imparted by the HydroBoost

®

 Surface Mount Bottle Filling 

Station (On-Wall Bottle Filler). If necessary, install a Wall Support Carrier (not supplied). 

2.   

Ensure Water Supply Line

 and Drain Line are sized and located as specified in the Rough-in diagram. 

3.   

Ensure electrical Wall Outlet

 is within reach of Power Cord and is live with electrical power. See Warnings.

4.   

Test GFCI before proceeding: 

Push Test button to ensure power cuts off. Then push Reset before operating. 

5.   

Attach Service Stop Valve

 (not supplied) to Water Supply line orienting the 3/8"O.D. female compression outlet 

horizontally to the left. Purge water line and test for leakage. Correct any leakage. 

6.   

Ensure package

 contains the following components: 

Wall Mounting (reference Rough-In, Fig. 1, Page 2)

1.   

Remove Bottom Cover from Bottle Filler

 by removing two(2) screws from bottom of unit. Use a 5/32" hex

 

wrench (not supplied). Remove and place aside new Filter Cartridge shipped inside Bottle Filler. 

2.   

Remove Back Panel from Bottle Filler

 by removing two(2) screws from top of unit that secures the Top Cover. 

3.  

 Fasten Back Panel

 to structurally secure wall thru eight(8) 7/16" obround holes with fasteners appropriate

 

for wall type. Locate Back Panel as specified in Rough-In. If necessary, attach to Wall Support Carrier (not

 supplied).
4.   

Ensure Bottom Cover is not obstructed

 by the roughed-in Water and Drain Lines. Test by sliding Bottom

 

Cover up into Back Panel opening. If Bottom Cover is prevented from seating properly, reposition Water and/or 

Drain Lines slightly until the Bottom Cover fits easily.

5.   

Before hanging the On-Wall Bottle Filler,

 ensure the Insulated Waterline is routed inside of the Rear Cross

 

Member. If outside the Cross Member, reposition to inside or else the unit cannot be installed properly.

6.   

Hang the On-Wall Bottle Filler 

onto the Back Panel, aligning three(3) tabs into three(3) slots on Rear Cross

 Member. 
7.   

Secure Bottle Filler to Back Panel

 by replacing Top Cover on top of unit and fastening with two (2) supplied 

screws.

DISPENSING 

NOZZLE

INSULATED 

WATERLINE

POWER SUPPLY CORD

Note: Back cover not shown for clarity

Summary of Contents for HydroBoost HTHBSM-1A

Page 1: ...n of connecting this product to supply line pressure lower than 20 PSI or higher than 105 PSI is not covered by warranty IMPORTANT THIS IS AN INDOOR APPLICATION ONLY ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL TOOLS ITEMS REQUIRED BUT NOT SUPPLIED SERVICE STOP VALVE WITH 3 8 COMPRESSION OUTLET FASTENERS FOR WALL TYPE 8 REQ D SLIP JOINT DRAIN UNION OR COMPRESSION CLAMP 5 32 HEX W...

Page 2: ... LEGEND A RECOMMENDED WATER SUPPLY LOCATION 1 2 IPS MAXIMUM PIPE SIZE SERVICE STOP VALVE NOT FURNISHED B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D MAXIMUM PIPE SIZE C ELECTRICAL OUTLET THREE 3 CONDUCTOR GROUNDED LOCATE WITHIN SAFE REACH OF POWERCORD D 7 16 X 3 4 OBROUND MOUNTING HOLES FOR FASTENING BACKPLATE TO WALL FIG 2 B C A SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH I...

Page 3: ...Cover from Bottle Filler by removing two 2 screws from bottom of unit Use a 5 32 hex wrench not supplied Remove and place aside new Filter Cartridge shipped inside Bottle Filler 2 Remove Back Panel from Bottle Filler by removing two 2 screws from top of unit that secures the Top Cover 3 Fasten Back Panel to structurally secure wall thru eight 8 7 16 obround holes with fasteners appropriate for wal...

Page 4: ...a clean appearance gather and loop any extra Power Cord and secure to the underside of bottom Cover with supplied adhesive backed clip Instruction for Use 1 To activate water flow position mouth of water bottle or container under Dispensing Nozzle and in a continuous motion swing and hold container in front of Sensor Lens Hold until container is filled to level desired 2 To stop water flow pull co...

Page 5: ...allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter S...

Page 6: ...e display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display sho...

Page 7: ..._12PK 98543C 98544C 2000000503 98546C 98549C 98631C 2000000502 Filter WaterSentry Plus 12Pack Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V WATERSENTRY PLUS FILTER PARTS LIST See Fig 3 ITEM NO PART NO DESCRIPTION 1 2 3 55898C 1000005553 70792C Filter Assy 3000 G...

Reviews: