Service: Inspection/Replacement

         •        Inspect Bottle Filler and Cooler twice each year for proper operation and performance.

         •        Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

1.     Lower Front Panel

: To access the refrigeration system and plumbing connections, remove four (4) screws from bottom of cooler to remove the

        lower front panel.

Replacement Parts: Water Filter Parts List

Replacement Parts

Part No.

55898C

55898C_12PK

98546C

98549C

98552C

98631C

1000004771

98668C

98999C

99000C

1000001907

99002C

99003C

99004C

Description

Filter-WaterSentry Plus

Filter - WaterSentry Plus (12 Pack)

Kit - Aerator Replacement

Kit - Hardware & Waterway Parts

Kit - Retro Filter Mounting

Kit - Electrical Package 220V

Kit - Solenoid Valve Replacement 220V

Kit - Filter Mounting Cover

Kit - Drain Pad

Kit - Button Assembly

Kit - Top Cover Replacement

Kit - Gasket VR BF Tower/Basin

Kit - Reset Switch

Kit - Micro Switch

Item No.

1

2

3

Part No.

55898C

98926C

51469C

Description

Filter Assy-3000 Gal.

Kit-Filter Head Fitting Includes John 

Guest Fittings & 3/8” Elbow Fitting

Assy-Filter & Bracket includes Filter 

Head/Mounting Bracket/John Guest 

Fittings/Screws

For Replacement Parts, contact your local distributor or visit our website www.HalseyTaylor.com

2.     Bottle Filler Removal: Loosen but DO NOT remove the two (2) Mounting Screws from

        the sides of the Bottle Filler. Remove the two (2) Pinned Torx Head Screws from the Top Cover &

        remove the Top Cover. The Bottle Filler may then be lifted up and off the Water Cooler

        (The water line and Remote Reset Button Wires will still be connected from the Water Cooler to

        the Bottle Filler.).  

3.     Bubbler

: To remove the bubbler, first disconnect the electrical supply. The underside of the

        bubbler can be reached through the underside of the front section. Remove the cover and

        internal panel by removing the retaining screws. To remove the bubbler, remove the tubing from

the quick connect fitting and loosen the bubbler nipple by turning counter-clockwise.  Do Not 

Overtighten. After servicing, replace internal panel and cover and secure with retaining screws. 

Then replace the lower front panel and secure with four (4) screws.

4.     Cleaning Strainer on Solenoid Valve: To clean the strainer, unscrew the cap of the solenoid

        valve. Remove screen and rinse thoroughly with water. Insert screen back into solenoid valve

        and screw cap on. Make sure the o-ring is placed properly.

2222 Camden Court – Oak Brook, IL 60523 U.S.A – 630.574.8484

Bubbler

56305C

Bubbler Nipple

Basin

56305C

Summary of Contents for HydroBoost HTHBHVR8-25

Page 1: ...er installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have...

Page 2: ...upported securely Add fixture support carrier if wall will not provide adequate support 2 Install water cooler onto wall bracket and secure to wall Installation Water Line connection 1 Ensure Mains Wa...

Page 3: ...m MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm HTHBHVR8 ROUGH IN REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA...

Page 4: ...Bottle Filler Do not plug into electrical outlet 7 With the power cord waterline and reset button wires through the hole on top of water cooler place Bottle Filler on to mounting bracket on basin NOTE...

Page 5: ...how FLTR 0 The Green LED should be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE Depress the program button for approximately 2 s...

Page 6: ...ses o Protective gloves o Hex drives Service Adjustments 1 Temperature Control Factory set for 50 F 5 10 C 5 water under normal conditions To adjust water temperature turn screw clockwise for colder c...

Page 7: ...ilter Head Mounting Bracket John Guest Fittings Screws For Replacement Parts contact your local distributor or visit our website www HalseyTaylor com 2 Bottle Filler Removal Loosen but DO NOT remove t...

Reviews: