background image

97715C (Rev. B - 5/04)

 HRFGEBP_A, HRFGSBP_A

PART NO.

ITEM NO.

PARTS LIST

Drain

Drain-Aztec Gold

Scr, 10-24 x 1/2 PH TR HD-Z

Nut-reg. retain 1-1/8 - 24

Bottom - Plate (HRFG-E)

Bottom - Plate (HRFG-S)

Strainer-Beehive

Strainer-Beehive Aztec Gold

Hex - Nut

Ferrule-Tailpipe

Ferrule-Tailpipe Aztec Gold

Push Button

Push Button-Aztec Gold

Push Button Sleeve

Push Button Sleeve-Aztec Gold

Regulator Holder

Bubbler Assy

Bubbler Assy-Aztec Gold

Push Button - Extension

Fountain - Galaxy Gray (HRFG-E)

Fountain - Galaxy Gray (HRFG-S)

Fountain - Golden Sand (HRFG-E)

Fountain - Golden Sand (HRFG-S)

Fountain - Black (HRFG-E)

Fountain - Black (HRFG-S)

Regulator

Screw #6-32 x .31" Set

Strainer

Panel - Back Galaxy Gray (E)

Panel - Back Galaxy Gray (S)

Panel - Back Black (E)

Panel - Back Black (S)

Panel - Back Golden Sand (E)

Panel - Back Golden Sand (S)

Panel - Back Stainless Steel(S)

Panel - Back Stainless Steel(E)

Bubbler Locknut

Gasket - Black

Insert - Threaded

Nipple Assembly

Wall Plate Assy HRF-SBP

Wall Plate Assy HRF-EBP

Nut - Regulator Mounting

Screw #6-32 x .12" Set

Poly Tubing (Cut To Length)

LK464

LK464AG

112627543890

15005C

27658C

27201C

40038C

45364C

40045C

40619C

45360C

45662C

45408C

45738C

45750C

50986C

51544C

45396C

56087C

56053C

55969C

56057C

55970C

56056C

56025C

61313C

70022C

55996C

56028C

56031C

56027C

56030C

56029C

56032C

23187C

23189C

70012C

100322740560

75554C

15029C

28158C

28170C

45736C

70023C

56092C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

DESCRIPTION

Orifice Assy:

 Mineral deposits on orifice can cause water flow to spurt or not regulate.  Mineral deposits may be removed from the

orifice with a small round file not over 1/8" diameter or small diameter wire. 

CAUTION: DO NOT

 file or cut orifice material.

Stream Regulator:

 If orifice is free of material deposits, regulate flow as in instructions on page 3(Step 7) or page 5(Step 9).  If

replacement is necessary, see parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings:

 Cooler is provided with lead-free connectors which utilize an o-ring water seal. To

remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(See Figure 6, Page 7).  To

insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".

CAUTION: Cleaning of Aztec Gold Models requires special care.  

Outer surfaces must be cleaned with detergent or mixture of

vinegar and water only, rinsed and wiped dry.  Abrasive and acidic cleaners may eventually damage the Aztec Gold finish.

TROUBLE SHOOTING & MAINTENANCE

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

PAGE 8

Summary of Contents for HRFG-EBP

Page 1: ...LEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES ISACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUND...

Page 2: ...INISHED FLOOR HRFG EBP HRFG SBP ROUGH IN MARBLYTE BACK PANEL DETAIL 1 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D...

Page 3: ...d by reason of connecting these products to supply line pressure lower than 20 PSIG or higher than 105 PSIG is not covered by warranty 7 Check stream height from bubbler Stream height is factory set a...

Page 4: ...ER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 6 5 8 168mm FROM THE WALL C 1 1...

Page 5: ...ghten Over tightening will crack the Marblyte Fountain 6 Remove elbow from end of p trap item 1 and attach it to drain tube Re attach elbow to p trap and cut waste tube to required length using plumbi...

Page 6: ...97715C Rev B 5 04 HRFGEBP_A HRFGSBP_A FIG 3 8 12 9 BASIN 3 14 24 6 10 SEE FIG 7 TOP VIEW 17 22 19 18 1 21 2 4 20 16 11 5 7 SEE FIG 3 13 FIG 4 PAGE 6 23 15 25...

Page 7: ...LLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE FIG 6 OPERATION OF QUICK CONNECT FITTINGS FIG 5 NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISH...

Page 8: ...028C 56031C 56027C 56030C 56029C 56032C 23187C 23189C 70012C 100322740560 75554C 15029C 28158C 28170C 45736C 70023C 56092C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DESCRIPTION...