background image

97715C (Rev. B - 5/04)

HRFGEBP_A, HRFGSBP_A

PAGE 3

1.  

Wall should already be framed for the fountain

 using the positioning dimensions shown in Fig. 1.

      Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight).

2.  

Install rough-in plumbing

 as shown in Fig. 1.  Run supply water inlet line and connect to a

     service stop (not provided).  Turn on supply water and flush thoroughly.  Close water supply.

3.  

Remove bottom access panel 

from fountain basin and save the screws. Install the fountain to the back

     panel and wall using (4) 5/16" bolts and washers (not provided).  Bolts should be long enough to securely

     fasten the fountain to the wall.  Tighten securely, but do not over tighten.  Over tightening will crack the

     Marblyte Fountain.

4.  

Remove elbow from end of p-trap

 (item 1) and attach it to drain tube.  Re-attach elbow to p-trap and

     cut waste tube to required length using plumbing hadware and trap as guide.

5.  

Make water supply connections

 from service stop to the fountain strainer (item 16) by inserting the

     water inlet line into  the inlet side of strainer until it reaches a positive stop about 3/4", (See Figure 6,

     Page 7).  Turn on water supply and check for leaks. Newly installed water supply line should be

     insulated after leak check is completed. 

DO NOT SOLDER TUBES INSERTED INTO THE STRAINER

     AS DAMAGE TO THE O-RINGS MAY RESULT.

6.  

These products are designed 

to operate on 20-105 PSIG supply line pressure.  If inlet pressure is

     above 105 PSIG, a pressure regulator must be installed in the supply line.  Any damage caused by

     reason of connecting these products to supply line pressure lower than 20 PSIG or higher than 105 PSIG

     is not covered by warranty.

7.  

Check stream height from bubbler.

 Stream height is factory set at 45-50 PSI. If supply pressure

     varies greatly from this, remove items 8 & 12 (See Figure 3, Page 6) by loosening set screw (item 15)

     and adjust the screw on regulator (item 14). Clockwise adjustment will raise stream height and counter-

     clockwise  adjustment will lower stream height. For best adjustment stream height should be approxi-

     mately 1-1/2" (38mm) above the bubbler guard (See Figure 7, Page 7).

8.  

Replace bottom access panel 

to fountain basin using screws provided. Tighten securely.

INSTALLATION INSTRUCTIONS

MARBLYTE BACK PANEL

Care and Maintenance of Halsey Taylor Marblyte Fountains

Marblyte provides an exremely durable, nonporous surface which resists staining.  Care is very simple.

Routine cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is

normally needed to give many years of trouble free service.  Cleaners left standing on the fountain surface

can dull the surface finish.  Be certain to rinse all cleaning agents completely and polish with a soft cloth.

Harsh abrasive cleaners are not required and should not be used.

Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple

scratches and stains.  Cigarette burns can normally be removed without noticeable effect.  Deeper

scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a green Scotchbrite

pad.

To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like

products will keep the finish looking like new.

Summary of Contents for HRFG-EBP

Page 1: ...LEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES ISACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUND...

Page 2: ...INISHED FLOOR HRFG EBP HRFG SBP ROUGH IN MARBLYTE BACK PANEL DETAIL 1 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D...

Page 3: ...d by reason of connecting these products to supply line pressure lower than 20 PSIG or higher than 105 PSIG is not covered by warranty 7 Check stream height from bubbler Stream height is factory set a...

Page 4: ...ER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 6 5 8 168mm FROM THE WALL C 1 1...

Page 5: ...ghten Over tightening will crack the Marblyte Fountain 6 Remove elbow from end of p trap item 1 and attach it to drain tube Re attach elbow to p trap and cut waste tube to required length using plumbi...

Page 6: ...97715C Rev B 5 04 HRFGEBP_A HRFGSBP_A FIG 3 8 12 9 BASIN 3 14 24 6 10 SEE FIG 7 TOP VIEW 17 22 19 18 1 21 2 4 20 16 11 5 7 SEE FIG 3 13 FIG 4 PAGE 6 23 15 25...

Page 7: ...LLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE FIG 6 OPERATION OF QUICK CONNECT FITTINGS FIG 5 NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISH...

Page 8: ...028C 56031C 56027C 56030C 56029C 56032C 23187C 23189C 70012C 100322740560 75554C 15029C 28158C 28170C 45736C 70023C 56092C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DESCRIPTION...