4705 FREEZE RESISTANT STEEL FOUNTAIN

ROUGH-IN DRAWINGS

1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. 

 Shown dimensions pertain to installation location.

    These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).

2. Remove bottom cover from fountain and save screws.

3. Install the fountain 

using bolts and washers (not provided).  Tighten securely.

4. Attach drain tube 

 to fountain and cut to required length using the freeze resistant box as a guide.

5. Install freeze-resistant box -  

see box instructions.

6. Replace 

bottom cover.