
PAGE 9
4410FR-FTN
97733C (Rev. G - 04/04)
INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN
Step 1 - Insert the 1/8 O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8 O.D. tube
coming from the fountain push button actuator into the connector. Trim any excess length.
Step 2 - Secure the 1/8 O.D. tube (Label C) to the waste line assembly. This line is a vent line and should be
open to the air.
Step 3 - Insert the 1/4 O.D. tube (Label E) into the 1/4 union (provided with valve assembly). Insert the 1/4 O.D.
water line coming from the fountain into union. Trim any excess length.
Step 4 - Insert the 1/4 O.D. tube (Label G) into the air gap assembly.
Step 5 - Secure the 1/4 O.D. tube (Label H) to the waste line assembly. This line is a vent line and should be
open to the air.
LABEL A
(ON/OFF CONTROL LINE
FOR BUBBLER ONE)
LABEL G
(DRAIN LINE)
LABEL E
(WATER LINE)
LABEL C
(VENT LINE)
LABEL H
(VENT LINE)
FOUNTAIN CONNECTIONS
FIG. 3
1/4" UNION
(SUPPLIED WITH VALVE)
MALE CONNECTOR
(SUPPLIED WITH FTN.)
FOUNTAIN CONNECTIONS
PLUMBING CONDUIT
(BY INSTALLER)
TO VALVE