Halsey Taylor 4410 Owner'S Manual Download Page 12

PAGE 12

4410FR-FTN

97733C (Rev. G - 04/04)

ITEM NO.

PART NO.

100147140560

100322740560

101570540560

15009C

15014C

28467C

40045C

45392C

45403C

45464C

45483C

45824C

45832C

45833C

45663C

56121C

66346C

66461C

75535C

75588C

75589C

75521C

75565C

75596C

56092C

56123C

28091C

PARTS LIST

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

NS

NS

NS

NS

NS

NS

DESCRIPTION

Drain Gasket

Washer

Drain Gasket

Nipple Assy. - Bubbler

Retaining Nut

Basin

Hex Nut 1-5/16"

Bubbler

Push Button Actuator

Drain Plug 1-1/2"

Drain Tube

Fountain Body

Access Panel

Bottom Cover

Push Button Sleeve

Drain Elbow 1-1/4"

Drain Tube

Fitting - 1-1/4" x 1-1/4"

Pinned Torx Screw 1/4-20 x .75"

Slip Joint Nut 1-1/4"

Gasket

Bit - Pinned Torx T-27

Fitting - Double Male Connector

Paint Touch-up (Pen)

Poly Tubing - 1/4"

(Cut To Length) - To Bubbler

Poly Tubing - 1/8" 

(Cut To Length) - To Actuator

Nameplate Insert

The Following Items are included with

the 4410FR Fountain

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

25

19

21

Bubbler Detail

Included with

SanitaryFR1

Valve

FIG. 9

Touch-up Paint

For minor scratches a Touch-up Paint Stick is available.  For repairing large defects,

off-the-shelf aerosol paint from your local hardware store can be used.  Listed are two

suggested brandnames.

•  Brandname: X-O

•  Brandname: Ace Hardware

   XO-11 Hunter Green

   Rust Stop / Machine & Implement International Green

Trouble Shooting

Insufficient Bubbler Flow:

 

Check that the shut-off valve is wide open.  Verify

minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body.  Clean

rubber orifice in flow control located below frost line in bushing between barb fitting and valve.

No Flow:

 

 Check for leaks in the air tubing going from the push button to the valve.  Make

sure the air tubing compression nut is hand tight.  Disconnect air tube from push button.

Place finger over air outlet. Push button to test diaphragm.  Tighten diaphragm cap screws.

Replace diaphragm if necessary.

Continued Insufficient or Varied Height of Bubbler Flow:

•

 Replace flow control.

•

 Check for kinks in the tubing.

•

 Remove the cleanout plug from the PVC column. Remove the valve assembly from the

PVC column by carefully pulling up on the strap and connecting tubing at the same time.

Pressure test the valve assembly for leaks. Check stream height from the bubbler. Stream

height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw

on the regulator (Item 11, Fig. 4, Page 10). Clockwise adjustment will raise stream and

counter-clockwise adjustment will lower stream. For best adjustment stream height should be

approx. 1-1/2" (38mm) above the bubbler guard. Replace the valve into the PVC column.

Make sure the supply hose coils into the bottom of the PVC column without any kinks and

double check that the valve is positioned fully at the bottom of the PVC column. Cap the

PVC column.

Continuous Bubbler Flow:

 

Insure that push button is not obstructed and springs back

to normal position. Remove four screws which secure plastic diaphragm block to valve body.

Pull plastic and rubber diaphragm assembly out of valve body.  Locate tiny hole in rubber

diaphragm just under lip of plastic part.  Clean debris from this hole.  Inspect valve seat for

grooves.  If valve seat was OK and diaphragm hole was free from debris, inspect rubber

button located at center of floating steel disc in valve diaphragm block assembly.  If button is

worn, turn disc over or replace it.  If diaphragm and seats are in good condition, stretch spring

slightly.  Spring is located behind floating stainless steel plate.  Insure that air bleed port on

valve plastic block assembly is not plugged.

22

26

26

21

19

23

30

29

27

25

36

34

35

31

33

28

37, 38

18

26

32

24

20

Summary of Contents for 4410

Page 1: ...ICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBAC...

Page 2: ...emoved for servicing the valve 5 We recommend that the top of the column be flush or slightly above the top height of the concrete pad 6 You should test the unit before you backfill Simply blow on the...

Page 3: ...VABLE BOTTOM COVER C 1 PVC DRAIN D PRESSURE FITTING 1 1 4 x 3 4 E CONNECTOR 1 1 4 TO 1 1 4 F 1 1 4 DRAIN TUBE G AIR CONTROL LINE H 1 4 WATER LINE J CONNECTOR FOR AIR CONTROL LINE SITE PREPARATION DETA...

Page 4: ...NSTALLING 97243C SINGLE VALVE CONTROL ASSY 1 Prepare trench for water supply and waste drain lines if required by local codes The hole should be deep enough to accommodate the PVC column and 5 cubic f...

Page 5: ...7243C 45787C 45788C 45789C 45790C 55960C 75565C 75521C 75596C 56092C 56123C 28091C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 NS NS NS NS NS Drain Gasket...

Page 6: ...mn Additional porous fill and drain pipe may be required due to local ground conditions Cut the PVC column to fit desired bury depth Set PVC column in excavating pit 2 Lay drain lines and water supply...

Page 7: ...PAGE 7 4410FR FTN 97733C Rev G 04 04 SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN WHEN USING THE SANITARYFR1 VALVE FIG 1...

Page 8: ...SITE PREPARATION DETAIL FOR THE 4410FR FTN WHEN USING THE SANITARYFR1 VALVE 1 1 4 DRAIN TUBE SUPPLIEDWITHFTN AIR GAP ASSY SUPPLIEDWITHVALVE 1 1 2 DRAIN TUBE SUPPLIEDBYINSTALLER Detail A LEGEND A ACCE...

Page 9: ...ert the 1 4 O D tube Label E into the 1 4 union provided with valve assembly Insert the 1 4 O D water line coming from the fountain into union Trim any excess length Step 4 Insert the 1 4 O D tube Lab...

Page 10: ...PAGE 10 4410FR FTN 97733C Rev G 04 04 Detail B 13 15 2 14 5 3 11 4 12 5 6 6 5 13 15 10 See Detail B FIG 4 FIG 5 Stream Height Adjustment...

Page 11: ...older Regulator Nut Poly Tubing 1 4 Cut To Length To Bubbler Poly Tubing 1 8 Cut To Length To Actuator Canister Trap Adaptor 1 1 2 x 1 1 4 Air Gap Assy Fitting 1 2 Union w Strainer Regulator Fitting E...

Page 12: ...ton to the valve Make sure the air tubing compression nut is hand tight Disconnect air tube from push button Place finger over air outlet Push button to test diaphragm Tighten diaphragm cap screws Rep...

Reviews: