OEM Softener System Setup Quick Reference
This is a quick reference setup procedure. See OEM Softener System Setup Detail for more
information on available settings.
STEP 1S
– Press NEXT and Down buttons simultaneously for 3 seconds. If screen in
step 2S does not appear in 5 seconds the lock on the valve is activated. To unlock press,
NEXT, Up, and SET CLOCK in se quence, then press NEXT and Down si mul ta neous ly for 3
seconds.
STEP 2S
– Choose Softening using Down or Up buttons. Press NEXT to go to Step 3S.
Press REGEN to exit OEM Softener System Setup.
STEP 3S
– Enter the ion exchange capacity in grains of hardness as calcium carbonate for
the system based on test data using Down or Up buttons. Press NEXT to go to Step 4S.
Press REGEN to return to previous step.
STEP 4S
– Enter the pounds of salt per regeneration using Down or Up buttons. Press
NEXT to go to Step 5S. Press REGEN to return to previous step.
STEP 5S
– Backwash: Select “NORMAL” or “LONGER” using Down or Up buttons. See
Tables 4 or 5 for backwash times. Press NEXT to go to Step 6S. Press REGEN to return to
previous step.
STEP 6S
– Set Gallons Capacity using Down or Up buttons:
• “AUTO” (reserve capacity automatically estimated and gallons capacity au to mat i cal ly
calculated from grains capacity and water hardness);
• “oFF” (regeneration based on day override); or
• number of gallons (20 to 50,000).
See Setting Options Table for more detail. Press NEXT to go to Step 7S. Press REGEN to
return to previous step.
STEP 7S
– Set Refi ll option using Down or Up buttons:
• “PoST” to refi ll the brine tank after the fi nal rinse; or
• “PrE” to refi ll the brine tank two hours before the regeneration time set.
Press NEXT to go to Step 8S. Press REGEN to return to previous step.
STEP 8S
– Set regenerant downfl ow or upfl ow using Down or Up buttons:
• “dn” if the regenerant is to fl ow downward through the media; or
• “UP” if the regenerant is to fl ow upward through the media.
Prior to selecting a regenerant fl ow direction, verify the correct valve body, main piston,
regenerant piston, and stack are being used, and that the injector or injector plug(s) are in
the correct locations.
Press NEXT to go to Step 9S. Press REGEN to return to previous step.
STEP 9S
– Set Regeneration Time Option using Down or Up buttons:
• “NORMAL” means regeneration will occur at the preset time;
• “on 0” means regeneration will occur immediately when the gallons capacity reaches
0 (zero); or
• “ on 0” means regeneration will occur at one of the following:
• the preset time when the gallons capacity falls below the reserve or the spec i fi ed
number of days between regenerations is reached which ev er comes fi rst; or
• after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See Setting Options Table for more detail. Press NEXT to exit OEM Softener System Setup.
Press REGEN to return to previous step.
RETURN TO
NORMAL MODE
STEP 3S
STEP 2S
STEP 1S
STEP 4S
STEP 5S
STEP 6S
STEP 7S
STEP 8S
STEP 9S