7
5
-
-
MIN
MAX
FACTORY VALUES
SAFETY FIELD CONFIGURATION (RELAY 2)
3 s
max. 30 s
Wait for the sensor to learn its environment
or lock it by remote control.
Launch a teach-in after changing the sensor position or when new objects are added to or changed in
the detection zone.
During teach-in, the detection field should be free of snow buildups, heavy rain, snowfall, fog or other
moving objects.
During teach-in, the sensor learns its surroundings and adapts the
detection field shape to these. Objects in the detection field will
be cut out.
WIDTH
HEIGHT
0.5 m
5.0 m
0.5 m
5.0 m
no field
Ex:
for a field width of 3.2 m
FIELD DIMENSIONS
SAFETY FIELD TEACH-IN
After the teach-in, the field dimensions can be reduced by remote control.
The field is by default limited to 5 x 5 m. You can adapt the dimensions by remote control, but they
can never be bigger than the shape which was defined by the teach-in.