XPander Sounders and Sounder Visual Indicators

 

Sounders and Sounder Visual Indicators 

 

XPander  XPander  sounders  can  be  wall  or  ceiling  mounted  and  use  a  bi

-

directional  monitored  radio  platform  to 

communicate. They feature 32 selectable tones, including the Apollo tone, and a self test which causes a fault signal to be 

sent if the sounders fail to operate. The selftest feature is activated by a DIL Switch. 

 

The address of a sound or a sounder/visual indicator is set at the commissioning stage by means of an XPERT card. 

 

The sounders and sounder/visual indicators are powered by two packs of batteries, one with three 

AA

” 

and one with three 

C

” 

size alkaline batteries which provide a working life of typically 3

-

5 years. The three

-

year life includes weekly tests and a 

half

-

hour sounding in a fire condition.

 

The Sounder Visual Indicators incorporate audio and visual signalling within one unit. 

 

Sound output: 100dB(A) 

 

Individual parts may be ordered separately. 

 

These products are tested and approved to the following : AS 7240

-

5, AS 7240

-

7, and AS 7240

-

25.

 

Item Numbers 

 

4107

-

8301

 

XPander Sounder and Sounder Base

 

Item Numbers 

 

4107

-

8303

 

XPander Sounder Visual Indicator and Sounder Base

 

Product Variants

 

Part Number

 

Product Name

 

4107

-

8301 (Red)

 

Red Sounder with red base 

 

4107

-

8302 (White)

 

White Sounder with white base 

 

4107

-

8303 (Red) 

 

Red Sounder Visual Indicator with red base 

 

4107

-

8304 (Clear/White) Base) 

 

Amber Sounder Visual Indicator with white base 

 

4107

-

8305 (Amber/White Base) 

 

Clear Sounder Visual Indicator with white base 

 

Summary of Contents for Ampac XPander

Page 1: ...Product Guide Ampac addressable range expansion Wireless Minimises disruptions to buildings and occupants Enables rapid retrofit or temporary solution AS7240 25 Dual batteries for enhanced integrity...

Page 2: ...either impracticable or undesirable It may also be used in sites with discrete buildings which need to be connected to a central control panel but where wiring might present problems XPander has been...

Page 3: ...here to Use Optical Detectors 10 Detector Operating Principles 10 Technical Data 10 Contents XPander MultiSensor Smoke Detector 11 Where to Use MultiSensor Detectors 11 Detector Operating Principles 1...

Page 4: ...comprises of two types of interface the Radio Hub and the Radio Communications Cluster or RCC The Radio Hub communicates with the control panel using the XP95 addressable two wire power and communica...

Page 5: ...s for ease of installation Radio Communications Fire detection systems are life saving systems and must therefore be highly reliable in use Radio communications have been developed to a point where hi...

Page 6: ...included in the booklet supplied with the survey kit and is also available from the Ampac website Training in the technique of surveying a site and designing an XPander system is mandatory Optical Sm...

Page 7: ...arily developed to enable fully wireless fire alarm systems to be designed providing almost unlimited configuration and installation options With each Hub capable of supporting up to 500 field devices...

Page 8: ...Diversity Interface transmits and receives signals via the integral Diversity Aerials which require no adjustment or maintenance This product is tested and approved to the AS7240 25 standards Item Nu...

Page 9: ...adio Hub supports up to four loops of detection and alarm devices An integral LCD display is provided on the Radio Hub along with function buttons to allow programming and diagnostics to be carried ou...

Page 10: ...articles over a wide range of angles The optical arrangement comprises an infrared emitter with a prism and a photo diode at 90 to the light beam with a wide field of view The detector s microprocesso...

Page 11: ...Photo electric detection of light scattered by smoke particles over a wide range of angles The optical arrangement comprises an infra red emitter with a prism and a photo diode at 90 to the light beam...

Page 12: ...measures the air temperature every 2 seconds A microprocessor stores the temperatures and compares them with preset values to determine whether a fixed upper limit the alarm level has been reached In...

Page 13: ...are tested and approved to the following standards AS 7240 5 AS 7240 7 and AS 7240 25 Item Numbers 4111 1303 XPander Combined Sounder and Optical Detector Item Numbers 4111 1501 XPander Combined Sound...

Page 14: ...e with three C size alkaline batteries which provide a working life of typically 3 5 years The three year life includes weekly tests and a half hour sounding in a fire condition The Sounder Visual Ind...

Page 15: ...nual Call Points are supplied with a resettable operating element as standard The call point uses the priority interrupt feature to give a fast response on operation This product is tested and approve...

Page 16: ...Output Unit All data is supplied subject to change without notice Specifications are given at 23 C and 50 relative humidity unless otherwise stated Technical data Supply Voltage 3V DC Relay Rating 2A...

Page 17: ...Adding Devices to the XPander Interface Up to 31 wireless detectors or alarm signalling devices may be assigned to a single interface Prior to adding devices to the Interface batteries must be enabled...

Page 18: ...s Eliminates cable problems Minimises disruption Enables rapid retrofit Modern styling Loop powered interface 915MHz Wireless addressing Radio base with wireless circuitry and battery compartment Auto...

Reviews: