background image

 

 

15 

15

MODEL VSA-X21 

Local Area Network 

IP Address  
The IP Address control shows the 
device IP address. 
Factory default is DHCP so the end 
users compatible DHCP router determines this address.  

 

Subnet Mask 
The Subnet Mask control shows the device subnet mask. 
Factory default is DHCP so the end users compatible DHCP router determines this 
subnet mask. 

 

Gateway Address 
The Gateway Address control shows the device Gateway address. 
Factory default is DHCP so the end users compatible DHCP router determines this 
address. 

 

DHCP  
The DHCP control shows the device DHCP status. 
Factory default is ON. 

 

When OFF, the IP address, Subnet Mask and Gateway address are 
determined by the settings in the other fields (after the UPDATE button is 
clicked). 

 

When ON, the IP address, Subnet Mask and Gateway address are 
determined by the end users compatible DHCP router. 

 

UPDATE   
The UPDATE control is enabled only when DHCP is OFF and a setting 
has been changed. 
Click this control after setting the IP address, Subnet Mask and Gateway address 
to the desired STATIC settings. 

 

Summary of Contents for VSA-X21

Page 1: ...ax 714 641 6698 Address Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail info hallresearch com CUSTOMER SUPPORT INFORMATION GUI User s Manual VSA X21 HDMI Audio Extra...

Page 2: ...our PC the Microsoft website has free downloads available 1 3 Software Installation If an earlier version of this particular software was previously installed UNINSTALL the program first from either t...

Page 3: ...n 2 2 USB Device Detection The VSA X21 software uses standard Windows drivers which automatically configure the USB port after connection and do not require the installation of any special USB drivers...

Page 4: ...s an XML extension the file will be interpreted as containing XML data otherwise the file will be interpreted as containing BINARY data Uploading invalid files will result in EDID corruption Export ED...

Page 5: ...ssigns a descriptive name to be given to the VSA X21 device that is a maximum 8 characters long The user is not allowed to change the device name with multiple devices connected The FACTORY DEFAULT na...

Page 6: ...M format 2 Chn Indicates HDMI audio received is LPCM format Video Output 5 ON OFF Indicates the state of the 5 vDC signal to the HDMI OUTPUT When the HDMI INPUT 5 vDC is connected the 5 vDC OUTPUT sig...

Page 7: ...e as well as being able to control the HDMI or ARC state Factory default is HDMI When OFF the HDMI IN audio is mixed and output on the amplifiers speakers and 3 5mm LINE OUT connectors When ON the HDM...

Page 8: ...video input is active HDBT over Local o The HDBT video input has priority over the Local video input o The Active Input controls disable in this mode o When a video source is detected on the HDBT inp...

Page 9: ...I KNOB DP Page Sensor Mute o A compatible page sensor connected on the rear terminal strip controls the MUTE function Compatible with Model VSA PGSNS o Whenever a signal is received of sufficient ampl...

Page 10: ...Delay control is enabled in this mode o The AUTO button in the WEBGUI is visible in this mode Video o The video source must actually send video in order to be detected o When video is received on the...

Page 11: ...that the device is still waiting for the specified event to occur o Triggered signifies that the device has detected the specified event Off Delay min The Off Delay min control field shows the device...

Page 12: ...l Port 2 Factory default is NONE for the X21 UI serial port when installed Pass Thru The Pass Thru control shows the device RS232 Pass Thru state as well as being able to control the ON or OFF state F...

Page 13: ...rate used is whatever the HDBT TX device used The HDBT RS232 stream will NOT be able to control the VSA X21 in this mode X21 UI The X21 UI control setting shows the device current setting as well as b...

Page 14: ...is ON When OFF no special processing of the HDBT RS232 is done When ON the device will send and receive RS232 commands to from the installed UHBX SW3 WP S for control IR Sender Receiver The IR Sender...

Page 15: ...ress Factory default is DHCP so the end users compatible DHCP router determines this address DHCP The DHCP control shows the device DHCP status Factory default is ON When OFF the IP address Subnet Mas...

Page 16: ...ecute the assigned function Type The button type can be set for Momentary or Toggle action Toggle buttons have two RS 232 strings associated with them Momentary buttons have one RS 232 string associat...

Page 17: ...ommand o Send any valid command to the device IR UI o Send IR code from X21 UI when installed Command when Function is set for Serial Serial UI or Serial HDBT The Command control field is where the us...

Page 18: ...WP S Communications Tab o UI KNOB DP Communications Tab o VSA PGSNS Communications and Advanced Tabs o X21 UI Communications and Button Tabs By default all buttons are disabled but have no Function or...

Page 19: ...alid When wrong checksums are detected the invalid checksum byte is highlighted in RED If an action is performed that affects the EDID such as initiating a learn process The checksum field might momen...

Page 20: ...he HDMI ARC volume will be reduced by the given Ratio Ratio The Ratio control shows the device Ducking Threshold ratio This is the percentage the HDMI ARC volume is reduced when the Ducking Threshold...

Page 21: ...21 21 MODEL VSA X21...

Page 22: ...22 User s Manual 22...

Page 23: ......

Page 24: ...ved Order toll free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail i...