Halcyon Explorer Manual Download Page 14

14

Eos/

Apollo 9 pack, and 3 hours for an Explorer/Eos/Apollo 13.5 pack. 

Warning

:

 Your Halcyon NiMH charger has  

 

a switch next to the power cord that allows 
the unit to be used with either 110-115 volt  

             or 220-230 volt outlets. Make sure that           
             you have the switch set correctly for your        
             conditions. Failure to set the charger for  
             the proper voltage can damage the                     
             charger's electronics.

The charge proceeds in two stages: 

Bulk Charge. Current is supplied to the battery pack at a rate pro-

grammed 

by Halcyon into the charger specifically for Explorer and

  Apollo packs.
•Topping Charge. Current is supplied at a fraction of the

 

bulk charge rate.

If the charger is plugged in to a power source but no battery is connected, 
the red light will indicate that the charger is searching for a battery to charge.
Once a battery is connected, the yellow light will indicate that the charger 
has entered the Bulk Charge state. Once the battery pack is completely
charged, the green light will indicate that the system has entered its Topping 
Charge state. In some cases heat or power fluctuations may trick the charger 
causing it to switch off prematurely. You
may check the charge of your pack by disconnecting the battery and waiting 
for 3-5 seconds, reconnect the battery and see if the yellow light appears.
For a fully discharged battery, the complete charging process should take 
approximately 1 hour for an Explorer/Eos 4.5 pack, 2 hours for an Explorer/

Engage the lid plugs with the battery cap's gold receptacles to provide power to 
the light (top). To charge the battery pack, push the charger's steel connectors 
completely into the battery pack's gold receptacles until the charger assembly 
rests on the lid (right).

p

!

The charging proceeds in two stages:


Summary of Contents for Explorer

Page 1: ...1 PRIMARY LIGHT SYSTEMS Explorer Eos Apollo Lighting Systems Manual HALCYON DIVE SYSTEMS...

Page 2: ...product and could subsequently result in injury to the user WARNING This manual provides essential instructions for the proper operation inspection and care of your new Halcyon lighting product Becau...

Page 3: ...Light Head Operation 9 Bulb Replacement 21 w HID 10 Canister Lid 11 Halcyon Power Systems 12 Battery Charging 13 Battery Storage 15 BurnTesting 16 Transporting 17 TroubleshootingYour Halcyon Light 18...

Page 4: ...pressure tested to 300 feet 91 meters Halcyon s three primary light lines meet the needs of every level diver and every imaginable dive environment The Explorer HID line utilizes a reliable and brill...

Page 5: ...lugs O ring sealed electrical connections Secure battery tray with Stainless Steel rods for additional protection Strain relief fittings on all Explorer cords Nickel plated brass sealing glands Larger...

Page 6: ...ately 20 000 hours and protected by a nearly indestructible light head The dual intensity LED allows an option to double battery run time see run time chart in Appendix 1 Simply flip the power switch...

Page 7: ...Metal halide bulbs operate at very high temperatures and pressures The glass lamps should be handled with care giving special attention to the quartz arc tube The Halcyon HID light is a DC lamp prope...

Page 8: ...beneficial for signaling The surface is spun and polished to our specifications and will not chip or flake like metal film vacuum coated reflectors Combined with the extended protective cowling on our...

Page 9: ...approximately 9 8 volts and will cause the light to alternate between normal intensity and notably reduced light output This flicker exists as a warning to indicate the light is nearing its capacity B...

Page 10: ...the bulb in your Halcyon 21 watt HID light become damaged it can be easily replaced by following these simple steps 1 Remove the Goodman handle and reflector assembly from the light head 2 Carefully...

Page 11: ...e The lid O ring does not require any lubrication The O ring groove on the lid should also be cleaned of any dirt or debris Be careful not to damage the sealing surface on the lid or canister During t...

Page 12: ...s fittings and stainless steel locking latches Halcyon lights use a lid integrated set of plugs to connect to the battery pack Simply line up the plugs with the gold edged receptacles on the top of th...

Page 13: ...esigned to top the battery pack back to a full charge when left connected to the battery during storage Halcyon recommends that you always store your battery pack connected to your battery charger if...

Page 14: ...harger is searching for a battery to charge Once a battery is connected the yellow light will indicate that the charger has entered the Bulk Charge state Once the battery pack is completely charged th...

Page 15: ...t the charger be matched with the battery 2 Do not allow the batteries to discharge deeply below about 9 volts 3 Do not allow the batteries to sit in a discharged state 4 Do not expose the batteries t...

Page 16: ...voltage The following steps will allow you to accurately determine your battery s burn time 1 Make certain that the battery has been fully charged For the best charge burn the battery for ten minutes...

Page 17: ...periencing problems with your HID light before the end of its expected lifespan take a second to inspect the bulb and ballast assembly Bulbs Inspect the bulb to make sure it is seated in the socket In...

Page 18: ...ompromised if the light head is sufficiently bumped or jarred during transport To check the HID bulb seating the lamp cover must be removed For a comprehensive discussion of this pro cess please see t...

Page 19: ...y pack s condition with the following steps 1 Verify that the charger is plugged into a properly functioning outlet Be sure that this outlet is not controlled by a wall switch that may be shut off ina...

Page 20: ...it and do not touch the bulb with bare hands Possible sites of water intrusion 1 Typically water leaks into the light as the result of dirty or damaged O rings Check the O rings in the area of the lea...

Page 21: ...a rubber mallet This action will tighten the connector and prevent a sloppy connection Another problem that might occur is a slight oxidation on the connector tip after several dives in salt water A l...

Page 22: ...NiMH or lead acid batteries You can expect battery capacity to decrease 10 to15 after 300 400 cycles My battery pack fell off the bench and hit the deck of the dive boat Now that battery does not wan...

Page 23: ...pollo battery pack or dry lid If you remove the protective Delrin caps the plastic shrink wrapping from your NiMH battery pack or disassemble the Halcyon dry lid you will void your Halcyon warranty Th...

Page 24: ...e battery A fully discharged battery will take approximately 3 hours to charge A fully charged battery will provide 1 hour of burn time on a single 200 watt Use of HMI in extremely cold conditions wil...

Page 25: ...er 20 hour run time 4 hour 13 5 amp Battery Pack 3 68 9 3cm OD 11 63 29 5cm L Weight 7 75 lb 3 5 kg Buoyancy 3 2 lb 1 5 kg Full Power 14 hour run time Half Power 28 hour run time 6 hours Appendix 1 Bu...

Page 26: ...is performed on all materials as described within this manual with the following exclusions A lifetime warranty to the original owner applies to Halcyon Delrin and UHMW canisters A 90 day warranty fr...

Page 27: ...unauthorized repairs modifications accidents fire or casualty This warranty does not extend to products whose serial number has been altered or intentionally defaced 4 Cosmetic damage such as scratch...

Page 28: ...28...

Reviews: