background image

7

8

The

 

Halco ProLED

®

 Nicheless LED Lights

 

are low voltage light fixtures. Improper 

wire gauge and/or wire length can affect the performance of these lights. Follow the 

guidelines below to determine the proper operation and optimum performance of 

the lights.

Voltages are determined by the measured voltage level at the bus bar where the 

transformer and cords are connected.

NOTE: 

Each color mode has a slightly different power draw.

Cord Length

Min Voltage

Max Voltage

  50 feet

9.4VAC

12.4VAC

100 feet

10.7VAC

13.2VAC

150 feet

11.82VAC

13.8VAC

WIRE GAUGE AND LENGTH

WARNING

Which could result in serious injury or death. A Ground Fault Circuit Interrupter (GFCI) 

for 120 Volt transformers should be used if required by the transformer manufacturer 

or if required by the local state or city code. When a GFCI is used, the conductors 

on the load side of the GFCI circuit shall not occupy conduit, boxes, or enclosures 

containing other conductors unless the additional conductors are also protected by a 

GFCI. Refer to local state and city codes for complete details.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION.

WARNING

Which could result in serious injury or death. The 

Halco ProLED® Nicheless LED Lights

 are only 

available for 12VAC power. For supply connection, use only an isolating low voltage power supply with 

ungrounded output, evaluated and listed by a Nationally Recognized Testing Laboratory (NRTL) for 

swimming pool use.

RISK OF ELECTRIC SHOCK OR ELECTROCUTION.

WARNING

WIRING TO A SWITCH

*If required by transformer manufacturer's instructions or by local state/city code requirements.

Figure 5:

 

Wiring 

Halco ProLED

®

 Nicheless LED Underwater Lights

.

Aqualink

®

 Aux Relay or Switch. 

Black

Line

GFCI*

Black

White

White

Green

White

Neutral

Ground

Ground

Black

120 volts to 12VAC 

transformer. 

Halco  ProLED

®

 Color-Changing  Light

 and 

Halco  ProLED

®

 White  Lights 

Nicheless LED

  light 

F

ixtures

 are operated through the light’s switch. No special 

controller or interface is required,  Use a junction box to connect and operate 

multiple lights with a single switch.

OPERATING THE HALCO PROLED

®

 COLOR CHANGING 

& HALCO PROLED

®

 WHITE NICHELESS LED LIGHTS

A 12-14 VAC Transformer must be used to power all 12VAC 

Halco ProLED

®

 

Nicheless LED Lights.
NOTE:

 For optimum performance Halco recommends not exceeding the load factor 

specified by the instructions included with the transformer.

To ensure maximum safety, only use a transformer that can supply 12VAC and is listed 

or certified by a Nationally Recognized Testing Laboratory (NRTL) as compliant with 

UL 379, Standard for Power Units for Fountain Luminaires, Swimming Pools and Spas.

12VAC INSTALLATION

To prevent the risk of fire which could result in property damage, void the warranty, as well 

as to ensure optimum performance from your 

Halco ProLED

®

 Nicheless LED Lights,

 do 

not exceed the load factor specified in the instructions provided by the manufacturer of 

the transformer.

WARNING

Summary of Contents for FLCN Series

Page 1: ...NOT RESPONSIBLE FOR SHIPPING OR TRANSPORTATION COSTS RELATED TO OBTAINING WARRANTY SERVICE IN NO EVENT SHALL HALCO BE LIABLE FOR ANY OTHER COSTS OR DAMAGES INCLUDING LOST PROFITS OR REVENUES LABOR CHA...

Page 2: ...circuit breaker before installing or servicing the light Failure to do so could result in death or serious injury due to electrical shock Before installing any underwater light fixtures or lamps read...

Page 3: ...e upgraded to a higher wattage model in the future RGB RGB W WHITE WATTS 8 Watts 20 Watts MINIMUM LENGTH FOR 1 5 PIPE 6 6 All products listed above are available in 30 50 100 and 150 feet cord lengths...

Page 4: ...rough bond beam and a minimum length for each style light See Light Info Charts p 4 Rigid 1 Rigid Electrical Conduit Sweep elbows only no 90 elbows Vertical installations such as bench and walk out lo...

Page 5: ...ionally Recognized Testing Laboratory NRTL for swimming pool use RISK OF ELECTRIC SHOCK OR ELECTROCUTION WARNING WIRING TO A SWITCH If required by transformer manufacturer s instructions or by local s...

Page 6: ...ling prior to the selected show color displaying no illumination will occur This is normal during the cycling process During this period the pool spa will be dark and precautions should be taken to av...

Page 7: ...g the Halco ProLED Nicheless LED Lights TROUBLESHOOTING Problem Possible Cause Action All lights fail to illuminate One or more lights are dim blinking or not working Colored lights out of sync Lights...

Reviews: