background image

1.  1.5" pipe must be installed through the bond beam with a minimum length of fourteen (14 inches,

followed by a one (1) inch conduit with sweeps. DO NOT use 90 degree elbows. It is highly   

recommended to use 1.5" pipe through out the entire width of the bond beam. (see Figure 2). 

  

2.  Snake the 2-Conductor electrical cord through the conduit outlet of the wall fitting, into the

conduit and up to the location of the 12VAC pool transformer. Cut off the cord, after allowing

for service and length of run to the transformer. A length of cord with 18" - 24" of excess

cord is recommended for the service loop. Pull the fixture snug to the wall fitting. 

NOTE:

 

THESE  STEPS  ARE TO  BE  PERFORMED  ONLY  AFTER  ALL  ELECTRICAL 

SYSTEM REQUIREMENTS ARE MET.

NOTE:

 

When using a 1 1/2" MIP fitting on the back of a SP-1022 or SP-1048 wall fitting, 

the interior dimension of the Spears or Dura brands of MIP are both too small for 

proper installation of the Halco ProLED

®

 Nicheless Lights.

INSTALLING THE HALCO PROLED® NICHELESS 

LIGHT FIXTURE

See chart on page 4 for min. 

length requirements.

1” minimum rigid conduit No 90° 

degree elbows.

4” Min. from water level to top of lens.

1.5” Pipe.

1.5” Threaded wall fitting.

Figure 2: Standard

 

Halco ProLED

®

 Nicheless Light installation with 1.5" pool wall fitting.

5

6

Figure 1:

 

Halco ProLED

®

 Nicheless Light installation with standard 1.5" plastic fitting.

48” min. Check local city and state for other j-box requirements.

12 VAC Class 2 Transformer or Junction Box.

8” minimum to maximum water level.

4” min to top of lens.

1.5” pipe through bond beam and a minimum length

for each style light. (See Light Info Charts, p.4)

Rigid 1” Rigid Electrical Conduit. Sweep 

elbows only, no 90º elbows.

Vertical installations such as bench and walk-out locations 

will use ALL of the same clearance requirements.

MAX POSSIBLE WATER LINE (top of copping)

3.  Using the included Lens Key, thread the light into the

wall fitting until it is snug. 

NOTE TO INSTALLER:

 Please provide the pool owner 

with at least 1 Lens Key upon completion of installation.

Figure 3:

 Lens Key Operation.

Tighten

Figure 4:

 

Standard Halco ProLED

®

 Nicheless Light installation with 1.5" pool wall fitting.

WIRING OPTIONS FOR CONTROLLING THE HALCO 

PROLED

®

 NICHELESS LIGHTS

NOTE:

 Always consider the cable length when calculating the input voltage at the 

transformer. The maximum service between a transformer and all the connected lights 

should not exceed 150 ft... in length. This includes the primary run from the

Junction Box (J-Box). 

Multiple  Halco  ProLED

®

 Color-Changing Nicheless Lights may be synchronized by 

being controlled on a single circuit, with a single transformer and switch, up to and not 

exceeding 400 watts.

12VAC Pool Transformer, see table in Wire 

Gauge and Length section for more details.

12VAC Pool Transformer.

NOTE: 

Service Loop 

not applicable for 

Junction Box Installations.

4” Min. from water level to top of lens. 

4” Min. from water level to 

top of lens. 

Allow 18”-24” slack 

for Service Loop. 

Conduit to 12VAC 

transformer. 

Vertical Installation for steps, Benches and Swim outs.

IMPORTANT: 

All

 

Halco ProLED

®

 Color-Changing Light Nicheless Lights

 

must be on the same circuit or switch, or tied into the same transformer in order  

to synchronize colors. Use only solid wire and bus style terminal connectors.

WARNING

Summary of Contents for FLCN Series

Page 1: ...NOT RESPONSIBLE FOR SHIPPING OR TRANSPORTATION COSTS RELATED TO OBTAINING WARRANTY SERVICE IN NO EVENT SHALL HALCO BE LIABLE FOR ANY OTHER COSTS OR DAMAGES INCLUDING LOST PROFITS OR REVENUES LABOR CHA...

Page 2: ...circuit breaker before installing or servicing the light Failure to do so could result in death or serious injury due to electrical shock Before installing any underwater light fixtures or lamps read...

Page 3: ...e upgraded to a higher wattage model in the future RGB RGB W WHITE WATTS 8 Watts 20 Watts MINIMUM LENGTH FOR 1 5 PIPE 6 6 All products listed above are available in 30 50 100 and 150 feet cord lengths...

Page 4: ...rough bond beam and a minimum length for each style light See Light Info Charts p 4 Rigid 1 Rigid Electrical Conduit Sweep elbows only no 90 elbows Vertical installations such as bench and walk out lo...

Page 5: ...ionally Recognized Testing Laboratory NRTL for swimming pool use RISK OF ELECTRIC SHOCK OR ELECTROCUTION WARNING WIRING TO A SWITCH If required by transformer manufacturer s instructions or by local s...

Page 6: ...ling prior to the selected show color displaying no illumination will occur This is normal during the cycling process During this period the pool spa will be dark and precautions should be taken to av...

Page 7: ...g the Halco ProLED Nicheless LED Lights TROUBLESHOOTING Problem Possible Cause Action All lights fail to illuminate One or more lights are dim blinking or not working Colored lights out of sync Lights...