Operation
2.2
Controls and display elements
2.2.1
Control panel
The individual functions of the buttons on the control panel are described
below. The respective activated functions are visible as corresponding sym-
bols in the multifunction display (MFD).
The electrical system is switched on and off with the key switch.
• Position 0: The electrical system is switched off. The key can be pulled out.
• Position 1: The electrical system is switched on.
• The software version is displayed for approx. 1 second on the MFD,
followed by the last service code for approx. 3 seconds if necessary. The
operating hours meter is then displayed.
Driving direction selection button Fig. 5-51
The driving direction is selected with this button. The driving direction can be
changed while driving.
• Push the button (A): Forwards gear
• Push the button (B): Reverse gear
Note
A warning signal is output when in reverse gear. The maximum
speed when reversing is half of the maximum speed when driving
forwards.
A
B