LUBRICATION POINTS
Latches & Hinges
The hinges and latches and all doors and covers
should be lubricated with oil every 500 hours. There
are numerous hinges and latches, make sure to
lubricate all of the following:
• Engine cover
• Main Broom Doors
• Seat Tracks
HYDRAULICS SYSTEM
Filling The Fluid Reservoir
CAUTION
DO NOT OVERFILL HYDRAULIC RESEVOIR TANK!
DO NOT USE TRANSMISSION FLUID!
NOTE: Fill the hydraulic fl uid reservoir when the
machine is cool and the hopper is in the
lowered position.
1. Open the engine cover.
2. Remove the dipstick. Fluid level should be
between the high and low marks on the dipstick.
3. If the fl uid level is not acceptable, add hydraulic
fl uid.
CAUTION
Minuteman International, Inc. recommends using:
Mobil DTE 10 Excel 32 hydraulic oil or equivalent.
Mobil DTE 10 Excel 32 - Viscosity, ASTM D 445
cSt @ 40°C (104° F): 32.7
cSt @ 100°C (212° F): 6.63
Changing The Hydraulic Fluid
1. Turn off the engine and engage the parking
brake.
2. Place a drain pan on the fl oor below the
reservoir.
3. Remove the drain plug located on the bottom
rear of the reservoir and allow the fl uid to drain.
4. Discard the fl uid in an approved manner, then
replace and retighten the drain plug.