Axel Johnson International 

 

 

 
 
SAFETY INSTRUCTIONS AND CAUTIONS 
(If operating the lifting table improperly, a person may be 
injured. Therefore, operate properly according to the following instruction.)
 

 

The lifting table is a movable lifter designed to lift or lower a rated load. Do not use it for 
other purpose. 

 

Do not allow a person to operate the lifting table, who does not understand its operation. 

 

It is forbidden to modify the lifting table 

without manufacturer’s written admission. 

 

It is necessary to use the spare parts designated by manufacturer. 

 

Make sure to keep a distance between the table and ambient objects enough to operate 
the lifting table safely. 

 

Keep the hydraulic system in clean and safe condition. 

 

The hydraulic power pack features an electric lowering control. The coils must be fed with 
the  required  voltage  as  described  on  those  coils.  The  power  supply  voltage  should  not 
exceed 

±

10% of the rated required voltage. 

 

Always do maintenance and routine check while the lifting table is unloaded. 

 

The lifting table is not waterproof and should be used in a dry environment. 

 

DAILY INSPECTION 

A daily inspection is an effective way to detect a malfunction or fault on the lifting table. Before operation, 
check the lifting table according to the following points. Remove the table from service if any malfunction 
or defect is found. 

 

Check all the terms of SAFETY INSTRUCTIONS AND WARNINGS/CAUTIONS. 

 

Check that all markings (warning, caution, capacity etc.) are clearly legible. 

 

Check the lifting table for scratches, bending or cracks. 

 

Check smooth movement of the table. 

 

Check if there is any hydraulic oil leakage. 

 

Check the vertical creep of the table. 

 

Check if all the bolts and nuts are firmly tightened. 

 

OPERATING THE LIFTING TABLE 

LOADING 

 

The maximum capacity of the lifting table is 1000 kg. Load should be distributed equally 
on the lifting table, do not load partially or concentrically. Ensure the balance of the loading. 

 
LIFTING THE TABLE 

 

Screw and loose emergency stop switch. 

 

Push the UP button and power pack starts to work to lift the load. 

 

Loose the UP button and power pack stops working. 

 
LOWERING THE TABLE 

 

 Push the DOWN button and the table will lower. 

 

 Loose the DOWN button and the table will stop. 

 

NOTE 

 

The table is equipped with an aluminum guard to avoid accidental danger. 

 

If aluminum guard strikes an object while the table lowers, stop operation and check the 
lifting table. After making sure  there is no abnormality, strike the UP button slightly and 
then the electric system will function as before. 

 
 
 

Summary of Contents for NOSP1000HU

Page 1: ...w haklift com Lifting Solutions Group Axel Johnson International Rev 20200310 ORIGINAL INSTRUCTIONS K NN S ALKUPER ISEST K YTT OHJEESTA VERS TTNING AV ORIGINAL BRUKSANVISNING ELECTRO HYDRAULIC LIFTING...

Page 2: ...Do not use the lifting table if any malfunction or fault damage is found Make sure that there are no obstacles in the working area Do not put foot hand or any other part of the body in scissor mechan...

Page 3: ...CTION A daily inspection is an effective way to detect a malfunction or fault on the lifting table Before operation check the lifting table according to the following points Remove the table from serv...

Page 4: ...ydraulic system by listening its noise touch motor s surface Caution It is necessary to turn off the AC power supply before touching motor s surface Pay attention to clean or even replace the oil filt...

Page 5: ...Haklift Oy Asessorinkatu 3 7 20780 Kaarina Finland Tel 358 2 511 5511 sales haklift com www haklift com Lifting Solutions Group Axel Johnson International...

Page 6: ...ing limit switch if existed damaged Replace limit switch Table cannot lower Lowering limit switch or micro switch on safety guard damaged Electromagnetic valve dysfunctions Safety guard works Somethin...

Page 7: ...sti ennen laitteen k ytt nottoa Turvallisuusohjeita tulee noudattaa tarkasti Kaikki turvalaitteet tulee tarkistaa ennen k ytt l k yt p yt jos siit l ytyy pienikin vika tai toimintah iri Varmista ett t...

Page 8: ...ymp rist ss P IVITT ISET TARKASTUKSET P ivitt inen tarkastus on tehokas tapa huomata p yd ss oleva toimintah iri tai vika Tarkista nostop yd st seuraavat asiat ennen k ytt Tarkista ett kaikki TURVALL...

Page 9: ...lemalla sen ni sek koskemalla moottorin pintaa Huomio Virtal hde pit olla kytkettyn pois ennen kuin moottorin pintaa kosketaan Kiinnit huomiota ljysuodattimen puhdistukseen tai jopa uusimiseen kun p y...

Page 10: ...Haklift Oy Asessorinkatu 3 7 20780 Kaarina Finland Tel 358 2 511 5511 sales haklift com www haklift com Lifting Solutions Group Axel Johnson International...

Page 11: ...ttori toimi Laskun rajakatkaisin jos asennettu on viallinen Vaihda rajakytkin P yt ei laske Laskun rajakytkin tai turvareunan mikrokytkin on viallinen S hk magneettiventtiilin toimintah iri Turvareuna...

Page 12: ...eras innan drift Anv nd inte lyftbordet om n got fel uppt cks Se till att det inte finns n gra hinder i arbetsomr det Placera inte foten handen eller n gon annan kroppsdel i saxmekanismen genom ramen...

Page 13: ...lig inspektion r ett effektivt s tt att uppt cka funktionsfel och fel hos lyftbordet Kontrollera lyftbordet f re drift enligt f ljande punkter Produkten m ste tas bort fr n service om n got fel uppt c...

Page 14: ...emet genom att lyssna p dess ljud och vidr ra motorns yta Varning Det r n dv ndigt att st nga av n taggregatet f re ber ring av maskinens yta Var uppm rksam p att reng ra eller byta ut oljefilter efte...

Page 15: ...Haklift Oy Asessorinkatu 3 7 20780 Kaarina Finland Tel 358 2 511 5511 sales haklift com www haklift com Lifting Solutions Group Axel Johnson International...

Page 16: ...ytare om finns skadad Byt ut gr nsbrytare Lyftbordet s nks inte S nkande gr nsbrytare eller mikrobrytare p s kerhetsskyddet r skadat Elektromagnetisk ventil r dysfunktionell S kerhetsskydd anv nds N g...

Page 17: ...1 Hydraulic circuit Hydrauliikkapiiri Hydraulisk krets Hydraulic cylinder Hydraulisylinteri Hydraulisk cylinder Damper Vaimennin Spj ll Electromagnetic valve S hk magneettinen venttiili Elektromagneti...

Page 18: ...80 Kaarina Finland Tel 358 2 511 5511 sales haklift com www haklift com Lifting Solutions Group Axel Johnson International Fig Kuva Bild 2 Electric Principle Diagram 3 P S hk piiriin kytkent kaavio 3...

Page 19: ...c valve DC24V 1 11 SB3 Emergency stop button XB2 ES542C ZB BY9101 1 12 SB2 Down button XB2 BA21C 1 13 SB1 Up button XB2 BA21C 1 14 SQ1 Up limit switch D4V 8108Z 1 15 SQ2 Safety switch 2 16 SQ9 Down li...

Page 20: ...80 Kaarina Finland Tel 358 2 511 5511 sales haklift com www haklift com Lifting Solutions Group Axel Johnson International Fig Kuva Bild 3 Electric Principle Diagram 2 P S hk piiriin kytkent kaavio 2...

Page 21: ...rectifying diode IN4007 6 10 DF01 Electromagnetic valve DC24V 1 11 SB3 Emergency stop button XB2 ES542C ZB BY9101 1 12 SB2 Down button XB2 BA21C 1 13 SB1 Up button XB2 BA21C 1 14 SQ1 Up limit switch D...

Page 22: ...Haklift Oy Asessorinkatu 3 7 20780 Kaarina Finland Tel 358 2 511 5511 sales haklift com www haklift com Lifting Solutions Group Axel Johnson International...

Page 23: ...Hydraulic power pack 1 20 Retaining ring 20 2 69 Washer 10 2 21 Long wheel 2 70 Spring washer 10 2 22 Long bush 2 71 Screw M10x20 2 23 Nylon wheel axle 2 72 Height pressure hose 1 24 Internal scissor...

Page 24: ...ei vastaa toimittamiensa tuotteiden turvallisuudesta mik li niihin tehd n muutoksia asiakkaan toimesta tai niihin liitet n yhteensopimattomia komponentteja SWE SCM Citra Oy f rs krar att de nedan n m...

Page 25: ...A FIN Konedirektiivin 2006 42 EY liitteen VII osan A mukaisen teknisen tiedoston valtuutettu kokoaja SWE Bemyndigad att sammanst lla den tekniska dokumentfilen enligt bilaga VII del A till maskindirek...

Reviews: