11
Skin removal key
Short key →gross weight turns to net weight. Indication
lamp of net weight “Net” is on. Conduct skin removal
operation for multiple times.
Digit flicker position reduces.
Zero clearing key
Gross weight state resets weight. When the scale is in
net weight, dynamic state, saving state and out of
resetting range, zero clearing operation is invalid.
In setting, digit of flicker
position increases. In
adjustment of display,
accumulation is cleared.
Printing key
Short key → start up or print.
Printing format refers to
Appendix1
.
Long key → shut down.
Confirm operation, to save
setting data.
10.5 Parameter Setting
Setting entry:
Press the [Hold] button on the operating panel in the state of normal weighing.
If F1.14 = 0, you can set all the parameters within F1~F5.
If F1.14 = 1, you can only set all parameters within F2~F5.
If F1.14 = 1 and you need to set the parameters within F1 menu, you can press the calibration switch
button until the F1 menu is entered.
F1 Parameter Setting of Scale
F1.1 Measuring Range
Selectable parameters: 3~200000 (default value: 6)
F1.2 Decimal Places
Selectable parameters: 0 ---- no decimal point
0.0 ---- 1 decimal place
0.00 ---- 2 decimal places
0.000 ---- 3 decimal places (default value)
0.0000 ---- 4 decimal places
F1.3 Number of Divisions
Selectable parameters: 1 (default value), 2, 5, 10, 20, 50
F1.4 Calibration Unit
Selectable parameters: 0 ---- kg (default value)
1 ---- lb