19
2. Continuous output A format
The data transmitted by continuous output protocol A is present display weight.
Gross weight format: ww0000.000kg or ww0000.000lb
Net weight format: wn0000.000kg or wn0000.000lb
Example: gross weight of 15.000kg
w w 0 0 0 1 5 .
0 0 0 k g 0d 0a
Net weight of 15.000kg
w n 0 0 0 1 5 .
0 0 0 k g 0d 0a
Gross weight-15.000kg
w w -
0 0 1 5 .
0 0 0 k g 0d 0a
Note: the above position of the decimal point is determined according to that in the instrument.
3. Continuous output B format
Continuous output agreement B format:
1 2 3 4 5 6 7 8 9 10
11
12 13 14 15
16 17 18
HEAD1 , HEAD2 , DATA UNIT CR/LF
HEAD1
:
OL Upper overload or lower overload, or no zero clearing in startup;
ST the scale is in stable state;
US the scale is in unstable state;
HEAD2
:
GS gross weight
;
NT net weight
;
DATA
:
instrument display data
;
UNIT
:
kg or lb
;
CR/LF
:
new line.
Example 1
:
in stale state, gross weight is 18.000kg. sp = space.
S T , G S , sp sp 1 8 . 0 0 0 k g 0d 0a
Example 2
:
in unstable state, net weight is -0.200kg. sp = space.
U S ,
N T ,
-
sp sp 0 .
2 0 0 k g 0d 0a
Appendix 2. Printing Format Specification
F2.1 = 0, 1, 4, 6
,
print current resetting, press
『
』
.
REPORT
------------------------
Gross 0.200kg
Tare 0.000kg
Net 0.200kg