3
4. INITIAL SETUP
CAUTION
Increasing the angle of the handpiece receptacle will
cause an increase in the handpiece temperature.
NOTE :
You can put nozzles that are not in use on the radial tray
of the cleaner base.
Loosen the adjusting screws to change the angle of the handpiece
receptacle as you like, then tighten the screws.
A. Handpiece holder
●
Setup the handpiece holder
Following the instructions given in the illustration on the right,
assemble the handpiece holder.
Radial tray
Cleaner base
●
When the cleaning sponge is included in the PACKING LIST
The sponge is compressed. It will swell when moistened
with water. Before using the unit, dampen the sponge with
water and squeeze it to remove excess water.
CAUTION
Be sure the sponge is moistened with water before use to avoid damaging the nozzle.
1. Fit the small sponge pieces into the hollows in the
cleaner base.
2. Add an appropriate amount of water into the cleaner base.
The small sponge pieces will absorb water and help keep
the larger sponge damp at all times.
3. Dampen the large sponge, squeeze it to remove excess
water and put it on the cleaner base.
●
When the cleaning wire is included in the PACKING LIST
Following the instructions given in the illustration on the right,
put the cleaning wire on the cleaner base.
Operation:
First, remove any excess solder from the nozzle by thrusting
the nozzle into the cleaning wire.
(Do not wipe the nozzle against the wire. This may cause
molten solder to spatter.)
When the wire becomes dirty or loaded with solder, reposition
the wire until a clean surface is presented. When changing the
cleaning wire, lift the case top vertically to prevent solder debris
from falling out.
Cleaning wire
Cleaning
sponge
(Large)
(Small)
4
3. Set the HAKKO FR-4003 in the
handpiece holder.
4. Connect the hose from the HAKKO
FR-4003 to the vacuum outlet cap on
the HAKKO FR-400 station.
5. Plug the power cord into a grounded power
outlet. Ensure that the power switch is OFF
before plugging in the AC plug.
CAUTION
Be sure to ground this product as it is ESD
safe by design.
6. Turn the power switch ON.
Connect the hose.
Turn the power
switch ON
Control
Buttons
Vacuum
outlet cap
PART NAMES
Power Switch
5. OPERATION
C
Normal display screen
Receptacle
- Moving the cursor UP. Increases the value.
- Moving the cursor DOWN. Decreases the value.
- End of sequence (terminates a phase of a data entry mode).
UP
DOWN
ENTER
The HAKKO FR-400 has three controls
B. Station
CAUTION
Be sure to hold the plug when inserting or removing the handpiece cord.
●
Connection
1. Connect the power cord to the receptacle on the
rear of the station.
2. Connect the plug from the HAKKO FR-4003
to the receptacle on the HAKKO FR-400.
CAUTION
Connect the plug to the receptacle, aligning
the tab on the plug with the opening on the
receptacle.
Insert the plug into
the receptacle until
it seats.
To disconnect, pull the plug
from the receptacle while
pressing down the tab on
the plug.