![Hakko Electronics FR400-53 Instruction Manual Download Page 20](http://html1.mh-extra.com/html/hakko-electronics/fr400-53/fr400-53_instruction-manual_3326104020.webp)
●
Error Alarm
●
Ready Alarm
In the buzzer sound setting mode, which sets whether to sound the buzzer when a
error occurs.
When the set temperature alert setting mode is on, the buzzer sounds if you reached
the usable temperature.
1. Move the cursor to select “Error Alarm”.
After selecting, press <OK>.
2. ON and OFF will be switched alternately
if you press the <
↑
> or <
↓
> button.
3. Return to parameter setting display if you
press the <OK> button after setting.
2. ON and OFF will be switched alternately
if you press the <
↑
> or <
↓
> button.
3. Return to parameter setting display if you
press the <OK> button after setting.
1. Move the cursor to select “Ready Alarm”.
After selecting, press <OK>.
<↑>
<↓>
<OK>
S l e e p T e m p
L o w Te m p
E r r o r A l a r m
200゚ C
150゚ C
ON
<↑>
<↓>
<OK>
E r r o r A l a r m S e t
O F F
<↑>
<↓>
<OK>
L o w Te m p
E r r o r A l a r m
Re a d y A l a r m
150゚ C
OFF
ON
<↑>
<↓>
<OK>
Re a d y A l a r m S e t
O N
O F F
19
●
Pass. Lock
When enabling this function, you must enter a correct password to change a setting.
The options are as follows:
Lock
Partial
Unlock
1. Move the cursor to select “Pass. Lock”.
After selecting, press <OK>.
2. Using the <
↑
> or <
↓
> button, select an
option from Lock, Partial, and Unlock.
5. Using the <
↑
> or <
↓
> button, enter a
password. (Selection of three characters
from ABCDEF)
* When selecting Partial or Lock:
3. Specify whether password lock should be
enabled when changing set temperature,
preset selection, and offset temperature by
selecting ON or OFF. (Only when selecting
Partial)
4. After making all selections, press the <OK>
button. (Only when selecting Partial)
6. Return to parameter setting display
if you press the <OK> button after
setting.
: All setting changes require a password entry.
: Selection of whether or not to enter a password when changing set temperature, preset
selection, and offset temperature. All other setting changes require a password entry.
:
Any setting change does not require a password entry.
<↑>
<↓>
<OK>
E r r o r A l a r m
Re a d y A l a r m
P a s s . L o c k
OFF
OFF
OFF
<↑>
<↓>
<OK>
P a s s w o r d L o c k S e t
U n L o c k
Select
“Unlock”
Select
“Lock”
Select
“Partial”
<↑>
<↓>
<OK>
S e t T e m p
P r e s e t S e l
O f f s e t T e m p
OFF
OFF
OFF
<↑>
<↓>
<OK>
P r e s e t S e l
O f f s e t T e m p
O K
OFF
OFF
<↑>
<↓>
<OK>
P a s s w o r d S e t
***
O K