![Hakko Electronics FR400-53 Instruction Manual Download Page 11](http://html1.mh-extra.com/html/hakko-electronics/fr400-53/fr400-53_instruction-manual_3326104011.webp)
●
Vacuum Check
During suction, the gauge indicating sucking status is shown at the lower side
of the screen.
When “CHK” appears and you notice that the sucking force is weakening,
perform “Vacuum Check.”
1. Move the cursor to select “Vacuum Check”. After selecting, press <OK>.
2. Pull the trigger.
3. When “Clogging” appears, perform cleaning and replace filters.
C
Suction gauge
Sign of clogging
C H K
<↑>
<↓>
<OK>
S e t T e m p
O f f s e t T e m p
V a c u u m C h e c k
350゚ C
00゚ C
< E X I T >
V a c u u m C h e c k
P u l l T r i g g e r
< E X I T >
V a c u u m C h e c k
P u l l T r i g g e r
O K
< E X I T >
V a c u u m C h e c k
P u l l T r i g g e r
C l o g g i n g
No degradation in sucking force
Degradation in sucking force
9
●
Preset Temp
1. Move the cursor to select “Preset Temp”. After selecting, press <OK>.
Select the preset No. whose temperature setting you wish to change.
2. Entering from hundreds to units digit
Press the <
↑
> or <
↓
> to set the desired figure.
Only values from 3 to 5 can be selected when entering the hundreds digit.
(In ℉ mode, values from 6 to 9 can be selected.)
Values from 0 to 9 can be selected when entering the tens or units digits.
(The same values can be selected in ℉ mode.)
3. After entering the units digit, press the button to save the figure to the system
memory and begin heater control with new setting temperature.
4. To exit from each setting screen, scroll the screen, select <Exit>, and press the
<OK> button.
CAUTION
If power is switched off or lost during the execution of this procedure, no data
will be entered. The entire procedure must be repeated from step 1.
<↑>
<↓>
<OK>
O f f s e t T e m p
V a c u u m C h e c k
P r e s e t T e m p
00゚ C
Select the preset No.
<↑>
<↓>
<OK>
P 1 T e m p
P 2 T e m p
P 3 T e m p
350゚ C
400゚ C
450゚ C
<↑>
<↓>
<OK>
P R E S E T 1
T e m p S e t
50゚ C
<↑>
<↓>
<OK>
P R E S E T 1
T e m p S e t
3 0゚ C
<↑>
<↓>
<OK>
P R E S E T 1
T e m p S e t
35 ゚ C
<↑>
<↓>
<OK>
P 2 T e m p
P 3 T e m p
< E X I T >
400゚ C
450゚ C
10
CAUTION
The temperature range is from 350 to 500℃. ( 660 to 940℉)
●
If you enter a value outside the temperature setting range, the display returns to
the hundreds digit, and you have to enter a correct value.