![background image](http://html1.mh-extra.com/html/hakko-electronics/fm-204/fm-204_instruction-manual_3319041007.webp)
6
C. Desoldering station
CAUTION
• Be sure to unplug the cord by holding the plug.
• Securely insert the connecting cable all the way into the jack.
●
The HAKKO FM-204 detects when the iron is
removed from the iron holder and sends this
data to the station via the connecting cable.
That data is then used for various functions.
●
Connection
1. Connect the power cord to the inlet on the
rear of the station.
(Connect the plug from the MODEL FM-2024
to the receptacle on the HAKKO FM-204.)
The HAKKO FM-204 can be used without being
connected to a control box.
CAUTION
Connect the plug to the receptacle, aligning the tab on the
plug with the opening on the receptacle.
2. Put MODEL FM-2024 into the iron holder.
3. Connect the hose from the MODEL FM-2024
to the fi lter case cover on the HAKKO FM-204
Station.
4. Plug the power cord into a grounded wall
socket.
Ensure that the power switch is OFF before
inserting the AC plug.
Turn the power switches ON.
CAUTION
Be sure to ground this product as it is ESD safe by design.
5. Turn ON the power.
CAUTION
The HAKKO FM-204 does not function properly if the
power is turned on with the trigger pressed. Release the
trigger and then turn the power ON.
Jack to connecting cable
Connecting cable
Plug
projection
Push the plug in as far as it will go, and
try to remove it without pressing the
release pin. If it stays in the receptacle it is
properly seated.
Receptacle opening
FM-2024
24V
-70W
Insert all the way to the base.