background image

                        

Vacuum pick-up tool

 

       

 

 

Battery-powered suction pick-up tool with built-in vacuum pump  

 

Max. pick-up suction capacity is 120gf  

 

Antistatic material is used 

 

Model No. 

394-01 

Power supply  Two size AAA batteries  

Pad 

Conductive silicone rubber  

Battery life 

Approx. 30,000suction (with alkaline batteries) 

Suction capacity 120gf (with pad

Φ

10mm) 

Dimensions 

130(W)×29(H)×22(D)mm  

Weight 

43g  

* Weight (w/o batteries, nozzle, pad) 

Service life of battery 

Pickup repetition limit 

*

Continuous pickup time 

*

Approx, 30,000 pickup times 
( With alkaline batteries ) 

Approx, 15 hours 

*

1. 26 mm x 26 mm QFP is pickup for 2 seconds using a 10 mm dia pad and 

then released for 1 second. This cycle is repeated cominuously unit the QFP is 
no longer picked up. 

*

2. This is the time perlod from the moment 26 mm x 26 mm QFP starts being 

pickup using a 10 mm dia pad to the moment the QFP drops. 

 

Name 

Contents 

Accessories 

HAKKO 394 

Unit 

Bent Nozzle/1.1mm(with stopper) 
Pad/5 mm 
Pad/10 mm      AAA alkaline battery 

Summary of Contents for 394-01

Page 1: ...o batteries nozzle pad Service life of battery Pickup repetition limit 1 Continuous pickup time 2 Approx 30 000 pickup times With alkaline batteries Approx 15 hours 1 26 mm x 26 mm QFP is pickup for...

Page 2: ...ctor related works Pick up of SMDs Surface mount PCB assembly Conveyance of ICs The pick up tool is designed to suck up micro components used for PCBs etc and not to absorb dust If used to absorb dust...

Page 3: ...chip Only these 2 shapes are avilable for single use Use Nozzle with Pad Nozzle Part No A1165 A1486 Name Description Bent nozzle 1 1mm Straight nozzle 1 1mm Outside Diameter 1 65mm 1 65mm Figure Pad P...

Page 4: ...will not be flicked and lost For the HAKKO 394 a very fine bent nozzle with 0 26mm hole diameter A1198 which can be used for 0603 sized components is available The nozzle ensures safe pick up operati...

Page 5: ...A1165 Bent nozzle w stopper 1 1mm A1312 Pad 5mm A1311 Pad 10mm A1164 Bent nozzle 0 4mm A1198 Bent nozzle 0 26mm A1486 Straight nozzle w stopper 1 1mm A1166 Pad 3mm A1167 Pad 7mm B2690 Joint w filter B...

Page 6: ...then check that the suction force is sufficient If the suction force is not recovered even after replacement of batteries overhaul the unit according to the following procedures 1 Remove the bent noz...

Page 7: ...addition clean the inside of the joint and silicon tube If cracks breaks etc are observed in the joint or silicon tube Replace the joint and silicon tube with new ones HAKKO 394 Replacement Parts 6 R...

Page 8: ...7 Press fit the silicon tube fully into the joint and pump to the end Refer to Photos 9 and 10...

Page 9: ...er to Photo 1 If the suction force is not recovered even after overhauling it can be assumed that the pump has deteriorated In this case it is recommended to send the unit in for repair Send it to the...

Reviews: