![Hakko Electric Machine Works Co., Ltd. HAP2031 Handling Manual Download Page 25](http://html1.mh-extra.com/html/hakko-electric-machine-works-co-ltd/hap2031/hap2031_handling-manual_3300508025.webp)
24
USAGE EXAMPLE AND HOW TO SET PARAMETER
ex. 2) Temperature control with outer temperature controller
It becomes effective to set in put of outer temperature control.
℃
時.分
Hz
℃
熱風温度(PV)
温度設定(SV)/周波数/時間
top of parameter
block 1 mode.
℃
時.分
Hz
℃
熱風温度(PV)
温度設定(SV)/周波数/時間
outer control input
effective/not effective
setting code.
invalid with "OFF".
℃
時.分
Hz
℃
熱風温度(PV)
温度設定(SV)/周波数/時間
valid with "on".
*In power off condition of before or after parameter setting, referring
to 19 pages, connect outer temperature control input +terminal and
outer temperature control -terminal to out put of SSR control of
temperature controller. (DC12V pulse out put)
外部制御
熱 風
light on
hot wind
outer control
・Pushing "mode change key" long-time 1 second at opera-
tion mode.
蛯
Present value display changes "
" to "
" one
after the other.
・Pushing "
key" two times at "
" mode.
蛯
Present value display changes "
".
Set value display change "
".
・Push "mode change key", "
key" and "mode change key"
each one time in order.
蛯
set value display is changed in "
" and is fixed.
Outer control lamp lights on and it is available to
set outer temperature control in put.
・Pushing "mode change key" long-time 2 seconds.
蛯
Come back to operation mode.