31
HAKKI PILKE RAVEN 33
TRANSLATION
VERSION 1
CHANGING THE OIL OF THE MULTIPLIER GEAR
4.7
1.
Run the machine for a while in order
to warm up and mix the oils.
2.
Turn off the tractor and remove the
cardan shaft from the multiplier gear
splined shaft.
3.
Open breather cap A in Figure 30 (this
will allow the oil to drain more easily)
as well as drain cap B, and drain the oil
into a suitable container.
4.
Close drain cap B.
5.
Add
0.09 litres
of appropriate oil to
the angle transmission through the
breather opening. (The multiplier gear
is small, so approx. 1 dl of oil is suffi-
cient).
6.
Finally, close breather cap A (Figure
30).
Figure 30.
CONVEYOR MAINTENANCE
4.8
Replacing and tightening the in-feed conveyor belt
Replace the in-feed conveyor belt as
follows:
1.
Shut the machine down and discon-
nect it from its power sources.
2.
Raise and lock the in-feed conveyor
into the transport position. (See Sec-
tion 2.3).
3.
Move the belt joint to a suitable
height.
4.
Disconnect the joint by using pliers, for
example, to pull out pin A (Figure 31)
that holds the joint together.
Figure 31.