14
HAKKI PILKE RAVEN 33
TRANSLATION
VERSION 1
Electrically powered model
An electrically powered machine func-
tions with a power of 7.5 kW. The IP
value of the electric motor is 55. The
fuse must be a min. 20 A type C fuse.
The electrical cable must be at least 5 x
4 mm², and it is connected to the sock-
et in Figure 10. The recommended max-
imum length for the supply cable is 30
metres.
The firewood processor can be activat-
ed with the green remote starter but-
ton on the front section of the machine
(Figure 11). Use the red remote starter
button to turn off the machine.
If the electric motor rotates in the
wrong direction (i.e. the machine
makes an abnormal noise and the hy-
draulic functions are inoperable), the
current phase is incorrect.
We recommend using an extension
cord that allows you to switch the cur-
rent phase, or an adapter.
Note! The actual starter is located be-
hind the machine (Figure 10). If the
machine’s thermal relay is triggered,
remove the fault and reset the relay by
pressing the Stop button on the starter
behind the machine.
Note! If the extension cord does not
have a phase switch, the electrical
work related to changing the phase
must only be performed by an electri-
cian.
Note! Only connect the machine to a
fault current protected socket.
Figure 10. Electric motor connector.
Figure 11. Remote starter.