14
HakkiPilke 50 Easy
Version 1.2 2012
In an electrically-powered machine, the
connector of the optical measuring device must
be connected to the socket on the side of the
machine.
The splitter can be activated with the starter in
the control panel at the front of the machine. If
the electric motor rotates in the wrong
direction (i.e. the machine makes an abnormal
noise and the hydraulic functions are
inoperable), the current phase is incorrect. We
recommend using an extension cord that
allows you to switch the current phase or an
adapter that can switch the phase.
Note! If the extension cord does not have a
phase switch, the electrical work related to
changing the phase must be performed by an
electrician.
Figure 13. Connector of the optical measuring
device
Figure 14. Starter
Figure 14 b.