EN
11.3.
Descaling
Depending on the quality of water, scale
may deposit on the pocket tube of the
radiator and the tank, whereby descaling
should be performed every two years.
Descaling requires the emptying of the
tank, the disconnection of the electri-
cal circuit and the removal of the service
cover . After removing the service cover,
it is recommended to perform reassem
-
bling using a new sealing . When cleaning,
avoid damaging the protective surface
finish.
Perform mechanical cleaning only; no
other cleaning or disinfection is needed .
Figure 11.3.-1
Descaling is considered to be part of the maintenance, and it does not belong to
the activities covered by guarantee . However, due to the necessity of disconnect-
ing the circuit, putting back into operation must be performed by an authorised
service station (along with the review of the electrical connections).
11.4.
Limiter
Since its replacement requires the disconnection of the electrical circuit, the con
-
tainer must be powered off.
11.5.
Radiator
Its replacement requires the disconnection of the power supply; such replace
-
ment requires the disconnection of the electrical circuit.
The replacement of the ceramic heating element (radiator with pocket tube) re
-
quires the discharge of water from the container and the removal of the service
cover. For this design, the radiator is inserted in an enamelled steel pocket tube
protected from outside impacts, whereby the heating element has not direct con
-
tact with water. Due to this design, there is no failure due to scaling, the anode
has a longer expected service life than in conventional pipe radiator designs. We
absolutely recommend this design for regions where water is hard .
11.6.
Active anode
The hot water storage tank is additionally protected against corrosion by active
anodes. The service life of the active anodes is subject to the water quality and
the operating conditions. The condition of the anodes must be checked upon
each descaling operation, but at least once every two years.
Its replacement requires the disconnection of the power supply; such replace
-
ment requires the disconnection of the electrical circuit and the removal of the
service cover. After removing the service cover, it is recommended to perform re
-
assembling using a new sealing .
The technician determines the time of the next inspection. If the diameter of the
anode decreases by 10 mm anywhere, it must be replaced. After replacement
Summary of Contents for Smiley SY80R
Page 101: ...3 101 FR 1 8...
Page 102: ...2 102 SY80R SY120R SY150R 50 C 0 6 100 C 0 6 0 6...
Page 103: ...3 103 III 3 R http www hajdurt hu 36 52 582 787 E mail vevoszolgalat hajdurt hu...
Page 104: ...2 104 SY80R SY120R SY150R 2 1 PN10 0 65 0 05 100 C Rp1 2 3 201 2001 25...
Page 106: ...2 106 SY80R SY120R SY150R 100 5 14 3 5 1 0 6 100 C 1 2 1252122514 5 2 Rp1 2 G1 2 4 1 2...
Page 107: ...3 107 0 01 0 02 0 65 0 05 14 3 5 3 0 6 14 5 5 4 5 5 14 3 5 6 14 4 5 1 1...
Page 109: ...3 109 6 8 14 2 2 3 7 7 1 7 2 14 3 1 7 3 7 4 7 5 6 1 1...
Page 110: ...2 110 SY80R SY120R SY150R 8 8 1 8 2 8 3 1600 80 2400 120 150 8 4 E 01 E 02...
Page 113: ...3 113 9 1 2 60 C 9 1 3 ECO ECO 60 C 9 1 4 10 C 9 2 9 3...
Page 114: ...2 114 SY80R SY120R SY150R 9 4 1234 9 5 4 9 5 1 9 5 2 9 5 3...
Page 115: ...3 115 9 5 4 Eco 70 70 C Spec Fro 10 C 9 5 5 9 5 6 C 80 C...
Page 116: ...2 116 SY80R SY120R SY150R 9 5 7 9 5 8 C 5 C 9 5 9 H 9 5 10 L 40 C...
Page 117: ...3 117 9 5 11 SET Ld 0 0 1 2 1 15 1 31 1 2 4 7 1 2 4 8 16 1 2 3...
Page 120: ...2 120 SY80R SY120R SY150R 11 11 1 11 2...
Page 121: ...3 121 11 3 11 3 1 11 4 11 5...
Page 122: ...2 122 SY80R SY120R SY150R 11 6 10 11 7 11 8 11 1 11 3 11 6 11 3 11 5...
Page 123: ...3 123 12 12 1 Li Ion Li Po 3 7 550 5 x 30 x 40 C 0 50 C 3 7 V A 50 mA 12 2 A A...
Page 130: ...2 130 SY80R SY120R SY150R 15 MEGFELEL S GI NYILATKOZAT...