SY80R • SY120R • SY150R
9.1.4.
Lower right pictogram (Snowflake)
Solid blue – Frost protection mode, temperatures factory preset at 10 °C.
9.2.
Use of touch buttons
The entry of settings and operation are performed using three capacitive but
-
tons with proximity sensors (Left, Mode, Right) added active LED illumination.
„Buttons” are illuminated only when they are active in the given situation . There
are two ways to press a button: short press and holding. The installed acoustic
signaller returns a short sound, when „buttons” are touched. If you lift your fin
-
ger immediately, this is considered as a short press on the „button” activating the
associated function. If you hold your finger on the „button” for app. two seconds,
a second sound will be returned indicating that you have securely activated the
function associated with the long press on the „button”.
If there is no such function in the given situation, nothing will happen upon release
of the button. In certain cases, no function is associated with a short press on a
button (e.g. on the middle button sometimes).
9.3.
Start of changes
If the display shows some data, and the middle button
is active, you can modify the given data . To do so, touch
and hold the middle button . To avoid accidental changes,
this will activate the „child lock” function .
The display shows four lower segments, the places for characters to be entered
only. You can change the flashing value using the left and right arrows.
If a screen allows changing more than one values (month/day, hour/minute
etc.), you can select the value you wish to change by pressing the middle button.
Values changed take effect immediately (e.g. if you set the desired temperature
higher than the measured one, heating will be activated immediately).
You can leave the change mode by pressing and holding the middle button. Upon
expiry of one minute from the last press on a button, the change mode ends and
the default values appear on the display.
9.4.
Releasing the child lock
In the place of the flashing bottom segment, you can
change digits by touching the left or right arrow, and you
can jump from the active (flashing) digit to the next one
by shortly pressing the middle button.
You can release the child lock by entering the digits ’1234’ on the display and
pressing and holding the middle button. The child lock stays released for one mi
-
nute from the last pressing on a button; therefore you have to release it once
only, if you want to change multiple parameters. After expiry of one minute, the
default values appear on the display.
9.5.
Seven segment display screen
Measured and preset values are displayed on a 4 digit, seven segment clock
screen. The formats of data displayed are distinguished using decimal points, the
colon and the degree symbol. You can navigate between the data displayed using
Summary of Contents for Smiley SY120R
Page 101: ...3 101 FR 1 8...
Page 102: ...2 102 SY80R SY120R SY150R 50 C 0 6 100 C 0 6 0 6...
Page 103: ...3 103 III 3 R http www hajdurt hu 36 52 582 787 E mail vevoszolgalat hajdurt hu...
Page 104: ...2 104 SY80R SY120R SY150R 2 1 PN10 0 65 0 05 100 C Rp1 2 3 201 2001 25...
Page 106: ...2 106 SY80R SY120R SY150R 100 5 14 3 5 1 0 6 100 C 1 2 1252122514 5 2 Rp1 2 G1 2 4 1 2...
Page 107: ...3 107 0 01 0 02 0 65 0 05 14 3 5 3 0 6 14 5 5 4 5 5 14 3 5 6 14 4 5 1 1...
Page 109: ...3 109 6 8 14 2 2 3 7 7 1 7 2 14 3 1 7 3 7 4 7 5 6 1 1...
Page 110: ...2 110 SY80R SY120R SY150R 8 8 1 8 2 8 3 1600 80 2400 120 150 8 4 E 01 E 02...
Page 113: ...3 113 9 1 2 60 C 9 1 3 ECO ECO 60 C 9 1 4 10 C 9 2 9 3...
Page 114: ...2 114 SY80R SY120R SY150R 9 4 1234 9 5 4 9 5 1 9 5 2 9 5 3...
Page 115: ...3 115 9 5 4 Eco 70 70 C Spec Fro 10 C 9 5 5 9 5 6 C 80 C...
Page 116: ...2 116 SY80R SY120R SY150R 9 5 7 9 5 8 C 5 C 9 5 9 H 9 5 10 L 40 C...
Page 117: ...3 117 9 5 11 SET Ld 0 0 1 2 1 15 1 31 1 2 4 7 1 2 4 8 16 1 2 3...
Page 120: ...2 120 SY80R SY120R SY150R 11 11 1 11 2...
Page 121: ...3 121 11 3 11 3 1 11 4 11 5...
Page 122: ...2 122 SY80R SY120R SY150R 11 6 10 11 7 11 8 11 1 11 3 11 6 11 3 11 5...
Page 123: ...3 123 12 12 1 Li Ion Li Po 3 7 550 5 x 30 x 40 C 0 50 C 3 7 V A 50 mA 12 2 A A...
Page 130: ...2 130 SY80R SY120R SY150R 15 MEGFELEL S GI NYILATKOZAT...