Surface - Trough for filling with concrete, asphalt or paving:
Chapter 01: Mounting dimensions
The cover must be set in
concrete to a height of 240
mm. The top 50 mm allows
for paving or other
carriageway coverings to be
laid.
The locking or hinge side
must run in the direction of
travel.
For the optional add-on to the cover
with trough, with the option:
“Hydraulic opening using internal
cordless screwdriver actuator”, the
following dimensions must be
considered when designing the
concrete surround:
clear depth +414 mm
Paving finish:
Empty trough and no reinforcement on
the hinge boxes
Concrete finish:
Reinforcement in the lid and on the hinge
boxes
Execution asphalt:
retaining plates in the lid
Execution
asphalt
clear width +215 mm
clear width
clear width +215 mm
clear
d
epth
Status: 10-2021
Page 3 of 16