1.2 Technical Specification 

Card type 

Mifare-1 Card(S200MF)  / TM Card(S200TM) 

Card inductive distance 

3cm  /   1.18

” 

Unlock method 

Card, Code, Code + Card, Mechanical key 

Code length 

4-8 digits 

User capacity 

200 users 

Power supply 

4pcs AA batteries  / CR2032 3V(remote control version) 

Static current 

≤30uA 

Working current 

≤200mA 

Suitable Door Thickness 

38-50mm   /    1.5

”-1.97” 

Backup power terminal 

9V(at the bottom of front plate) 

Handle Orientation 

Reversible 

Initial Master code 

123456 

Initial Debug code   

0(After installed, press 

“0”,then”#” to open door directly, 

automatically become invalid after changing master code) 

 

2 Installation Instructions 

Product Structure Map 

 

 
 
 
 

Summary of Contents for S200TM

Page 1: ...HAIFUAN S200TM MF USER MANUAL...

Page 2: ...oduct instruction Item No S200MF S200TM Dimension 155X68 78MM 6 1 X 2 72 X 3 07 Material Zinc Alloy Weight 2 3 kgs 5 pounds 1 1 Standard Single latch Backset is adjustable between 60mm 2 3 8 and 70mm...

Page 3: ...cs AA batteries CR2032 3V remote control version Static current 30uA Working current 200mA Suitable Door Thickness 38 50mm 1 5 1 97 Backup power terminal 9V at the bottom of front plate Handle Orienta...

Page 4: ...4 Drill 31 32 or 1 hole in center of door edge for latch Check template for correct size for your latch application 2 2 Install Latch And Strike Plate 2 2 1 Insert latch in the hole keeping it paralle...

Page 5: ...under the inner back plate 2 5 2 Install inner back plate to door Fix three screws 2 5 3 Connect data line to inner plate 2 5 4 Install 4 AA alkaline batteries 2 5 5 Install out plate with two screws...

Page 6: ...ew Master Code again then You will hear 4 beeps indicator light extinguishes New Master Code set successful Note If there is no react after you press the the keypad dose not illuminate then take out a...

Page 7: ...ps front light flash blue and keypad illuminate 2 Input Master Code then You will hear two beeps 3 Input 01 then within 10 seconds before the indicator light extinguishes You will hear two beeps 4 Inp...

Page 8: ...s still valid You will hear two beeps 5 Input Code within 10 seconds before indicator light extinguishes then You will hear two beeps 6 Put the Card close to the inductive place within 10 seconds befo...

Page 9: ...ps 3 Input 03 then within 10 seconds before the indicator light extinguishes You will hear two beeps 4 Input Group No within 10 seconds before the indicator light extinguishes then Group No which you...

Page 10: ...eep twice second beep 3 times single use code added successful 7 After 15 seconds or press Exit Long time of beeps indicator light extinguishes Special note If there are some people around you while o...