background image

6

49-5000489  Rev. 1

ENGLISH  

Remote Control Features and Settings

10 .    SWING  UP/DOWN

 

Press the SWING UP/DOWN button to choose the position of 

the horizontal airflow louvers.

Status display of air flow 

          COOL/DRY:

          HEAT:

NOTE:

•  It is advisable not to keep the horizintal air flow louver in the 

downward position for an extended period of time in COOL or 

DRY mode. This may cause condensate water to form on the 

louver.

•  When turning the unit on, the remote control will automatically 

return the louver to the previous set swing position. When 

turning the unit off, the louver will rotate to the full open 

position prior to closing. 

11 .    SWING SIDE/SIDE Button (select models)

 

Press the LOUVER SIDE/SIDE button to choose the position of 

the vertical airflow louvers.

Status display of air flow

COOL/DRY/HEAT/FAN

NOTE:

•  When the humidity is very high, the condensate water may occur 

on the air outlet if all vertical louvers are adjusted  too far to the 

left or right.

•  When turning the unit on, the remote control will automatically 

return the louver to the previous set position. 

12 .   DISPLAY

 

Turns on and off the indoor display. Press the DISPLAY button 10 

times within 5 seconds to display the ambient temperature. The 

indoor will beep 2 times when the setting is successful. Press 

the DISPLAY button 10 times within 5 seconds again to display 

the setting temperature. The indoor will beep 4 times when the 

setting is successful. 
The default display temperature is the setting temperature.

13 .   SLEEP

 

Press the SLEEP button, the heat pump will operate the sleep 

function, the display light will be turned off after 20 seconds. the 

control logics are as following running in different mode.
1.  COOL or DRY modes 

One hour after SLEEP mode begins, the temperature 

setpoint will increase 1°F (0.5°C). 2 hours after beginning 

sleep mode the setpoint will increase 1°F (0.5°C). Seven 

hours after beginning sleep mode, the setpoint will decrease 

1°F (0.5°C). At the eighth hour the unit will be back to the 

original setpoint. This feature helps with achieving maximum 

efficiency and comfort while you sleep. See the image below.

1h

Rises 1℉

2h

7h

8h

In COOL, DRY mode

temp.setting

Unit stop

SLEEP operation starts

Rises 1℉

Decrease 1℉

Decrease 1℉

2.  Heat Mode 

One hour after SLEEP mode starts, the setting temperature 

will decrease 2°F. After 2 hours later, the setting temperature 

will decrease additional 2°F. after 5 hours,the setting 

temperature will increase 1°F, after 8 hours, the  unit will run 

according to the initial setting temperature, this feature helps 

with achieving maximum efficiency and comfort the your 

feeling while you sleep.

1h

2h

7h

8h

In HEAT mode

temp.setting

SLEEP operation starts

Decrease 2℉

Decrease 2℉

Rises 1℉

3.  AUTO mode 

the unit operates in corresponding sleep mode adapted to the 

automatically selected operation mode. 

NOTE:

•   When the unit is set to sleep mode, the fan speed will be 

set to low speed and cannot be changed.

•    When the TIMER function is set, the sleeping function 

cannot be set. If the sleeping function has been set and 

the user sets the TIMER function, the sleeping function will 

be canceled and the unit will be set to the timer function.

14 .   FOLLOW

 

Press the FOLLOW button, the air will follow the body no matter 

people stand or moving. See chart below.

15 .   SURROUND

 

Press the SURROUND button. The air will surround the body no 

matter whether people are standing or moving. See chart below.

Model

Detect Area

Louver Up/

Down

Louver Left/

Right

FOLLOW Detect person 

in single zone

Remote setting 

position

Swing in the 

direction of the 

person

Detect person 

in multi zones

Remote setting 

position

Swing 

automatically

Detect 

nobody

Keep the initial 

setting position

Keep the initial 

settings position

Model

Detect Area

Louver Up/

Down

Louver Left/

Right

SURROUND Detect 

person in 

single zone

Remote 

setting 

position

Keep the initial 

setting position

Detect 

person in 

multi zones

"Health airflow 

(up) in cooling 

mode 

Health airflow 

(down) in 

heating mode"

Swing 

automatically

Detect 

nobody

Keep the 

initial settings 

position

Keep the initial 

settings position

Summary of Contents for WJ26X27153

Page 1: ...ner s Manual Le manuel du propriétaire Manual del usuario YR HQ WJ26X27153 High Wall Duct Free System Système bi bloc sans conduits Sistema de Split sin Conducto 49 5000489 Rev 1 04 20 GEA F C APPLY SPEED ...

Page 2: ...2 49 5000489 Rev 1 ENGLISH ...

Page 3: ... model serial number information on this page To receive a 10 year compressor and parts warranty registration is required within 60 days of installation Thank you for purchasing this Haier product This installation manual will help you get the best performance from your new heat pump For future reference record the model and serial number located on the label on the side of your heat pump and the ...

Page 4: ...other appliance If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do These R410A heat pump systems require contractors and technicians use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R22 refrigerant only WARNING WARNING Keep batteries away from children This remote con...

Page 5: ...utton The TURBO function is used for speeding up the air flow to highest speed in heating and cooling mode The UI interface will display the TURBO icon Pressing the TURBO again or SPEED button will exit the Turbo function 7 QUIET Button The QUIET function is used for lowing the fan speed to the lowest speed The control will display the QUIET icon on the UI interface Pressing the QUIET button again...

Page 6: ... the eighth hour the unit will be back to the original setpoint This feature helps with achieving maximum efficiency and comfort while you sleep See the image below 1h Rises 1 2h 7h 8h In COOL DRY mode temp setting Unit stop SLEEP operation starts Rises 1 Decrease 1 Decrease 1 2 Heat Mode One hour after SLEEP mode starts the setting temperature will decrease 2 F After 2 hours later the setting tem...

Page 7: ...rt of operation The unit will run automatically in the following modes While in Manual Operation temperature and fan speed cannot be changed nor will it operate in timer or DRY mode Inserting the Batteries 1 Remove the battery cover 2 Insert 2 AAA batteries as illustrated noting battery polarity 3 Reinstall the battery cover NOTE The distance from the remote control to the receiver should be less ...

Page 8: ...shrinking due to temperature changes If the airflow is creating a loud noise during unit operation the air filter may be too dirty Odors The system circulates odors lingering in the airstream such as the smell of furniture paint and or cigarettes Mist or steam is blowing out During COOL or DRY mode the indoor unit may blow out mist or steam This is due to the sudden cooling of the indoor air In DR...

Page 9: ...49 5000489 Rev 1 9 ENGLISH ENGLISH For warranty detail please refer to installation manual Limited Warranty ...

Page 10: ...10 49 5000489 Rev 1 ENGLISH Notes ...

Page 11: ... de la pompe à chaleur et la date d achat Agrafez votre preuve d achat à ce manuel pour faciliter le service de la garantie en cas de besoin _______________________________________ Numéro de modèle _______________________________________ Numéro de série _______________________________________ Date d achat Pour enregistrer votre nouveau système sans conduit Haier allez sur la page haierductless com...

Page 12: ...proximité de cet appareil ou de tout autre Si vous vous débarrassez d un produit qui contient un frigorigène informez vous auprès de l organisme responsable d en disposer Ces systèmes de thermopompe R410A exigent que les entrepreneurs et les techniciens utilisent des outils des équipements et des normes de sécurité approuvés pour ce type de frigorigène N utilisez PAS un équipement certifié pour le...

Page 13: ...ration La fonction TURBO est utilisée pour accélérer la circulation d air à la vitesse la plus haute dans les modes chauffage et climatisation L interface utilisateur affichera le mot TURBO Presser TURBO de nouveau ou le bouton de vitesse du ventilateur vous fera quitter la fonction TURBO 7 Bouton QUIET silencieux La fonction QUIET fait passer le ventilateur à la vitesse la plus basse La télécomma...

Page 14: ... À la huitième heure l appareil retournera à la température de réglage initiale Cette fonction contribue à obtenir une efficacité et un confort optimaux pendant que vous dormez Voyez le schéma ci dessous 2 Mode HEAT Une heure après le début du mode SLEEP la température de réglage diminuera de 2 F Deux heures plus tard la température de réglage diminuera de 2 F supplémentaires Après cinq heures la ...

Page 15: ...squ à la dégager de la butée puis retirez le filtre dans un mouvement vers le bas 3 Nettoyer le filtre Utilisez un aspirateur pour enlever la poussière ou lavez le filtre avec de l eau Après le lavage séchez le filtre complètement 4 Fixez le filtre Fixez le filtre de façon que l étiquette FRONT avant soit face à l extérieur Assurez vous que le filtre est bien fixé derrière les languettes de retenu...

Page 16: ...température Un filtre trop sale peut être à l origine d une circulation d air bruyante durant le fonctionnement de l appareil Odeurs Le système fait circuler des odeurs qui persistent dans l air telles que peut en dégager meubles peinture ou cigarettes Production de brume ou de vapeur Dans les modes COOL climatisation ou DRY sec l unité intérieure peut souffler de la brume ou de la vapeur Cela est...

Page 17: ...49 5000489 Rev 1 17 FRANÇAIS Pour des renseignements détaillés sur la garantie veuillez vous reporter au manuel d installation Garantie limitée ...

Page 18: ...18 49 5000489 Rev 1 FRANÇAIS Remarques ...

Page 19: ...realizar un registro dentro de los 60 días desde el momento de la instalación Gracias por adquirir este producto de Haier Este manual del propietario le ayudará a lograr el mejor rendimiento de su nuevo acondicionador de aire Para referencia futura registre el modelo y número de serie ubicados en la etiqueta que se encuentra al costado de su bomba de calentamiento y la fecha de compra Abroche su c...

Page 20: ...stico Si se deshará de un producto antiguo con refrigerantes consulte a la compañía a cargo sobre cómo deshacerse del mismo Estos sistemas de bombas de calentamiento R410A requieren que los contratistas y técnicos usen herramientas equipos y estándares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado sólo para el refrigerante R22 ADVERTENCIA Mantenga las bat...

Page 21: ...quier otro botón para salir de esta función 6 Botón TURBO Turbo La función TURBO Turbo se usa para acelerar el flujo de aire hasta la velocidad más alta en el modo de calefacción y refrigeración La interface de usuario exhibirá el ícono TURBO Presionar TURBO nuevamente o el botón SPEED Velocidad hará que se salga de la función Turbo 7 Botón QUIET Modo Silencioso La función QUIET Modo Silencioso se...

Page 22: ...ión se reducirá 1 F 0 5 C En la octava hora la unidad volverá al punto de configuración original Esta función ayuda a lograr la máxima eficiencia y confort mientras usted duerme Lea la siguiente imagen 2 Modo HEAT Calor Una hora después de iniciado el modo SLEEP Inactividad la temperatura configurada disminuirá 2 F 2 horas más tarde la temperatura configurada disminuirá otros 2 F Luego de 5 horas ...

Page 23: ... y retire el filtro con un movimiento descendente 3 Limpie del Filtro Use una aspiradora para retirar el polvo o lave el filtro con agua Luego del lavado seque el filtro completamente 4 Adhiera el filtro Adhiera el filtro de modo que la etiqueta FRONTAL mire hacia afuera Asegúrese de que el filtro se encuentre adherido de forma segura detrás de las lengüetas de suspensión Si el filtro no se encuen...

Page 24: ...ura Si el flujo de aire está creando un ruido fuerte durante el funcionamiento de la unidad es posible que el filtro de aire también esté sucio Olores El sistema hizo circular olores que permanecieron en la circulación del aire tales como el olor de muebles pintura y o cigarrillos Se está emitiendo neblina o vapor Durante los modos COOL Frío o DRY Seco la unidad interna podrá emitir neblina o vapo...

Page 25: ...49 5000489 Rev 1 25 ESPAÑOL Para acceder a detalles de la garantía por favor consulte el manual de instalación Garantía Limitada ...

Page 26: ...26 49 5000489 Rev 1 ESPAÑOL Notas ...

Page 27: ...49 5000489 Rev 1 27 ESPAÑOL Funciones y Configuraciones del Control Remoto ...

Page 28: ... GARANTÍA IMPORTANT Do Not Return This Product To The Store If you have a problem with this product please call 1 877 337 3639 for the name and telephone number of the nearest authorized service center DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE IMPORTANT Ne pas Réexpédier ce Produit au Magasin En cas de problème avec ce produit veuillez composer le 1 877 337 3639 pour connaître le nom e...

Reviews: