background image

49-5000489   Rev. 1

7

ENGLISH  

Remote Control Features and Settings

Manual Operation (POWER Button) and Maintenance

16 .   AUTO

 

The heat pump will automatically select Cool, Heat, or Fan 

operation according to set temperature. When SPEED is set 

to AUTO the heat pump automatically adjusts the fan speed 

according to room temperature.

17 .   VACATION

 

10°C/50°F Heating sets the system to maintain 10°C/50°F. This 

is used to prevent freezing during long unoccupied periods of 

time.

18 .  TIMER ON/OFF

 

To set the Timer using the TIMER ON button, press the CLOCK 

UP/DOWN. The time will be changed by 1 minute. Press the 

APPLY to confirm the setting. Press the TIME OFF button to 

cancel the timer function.

19 .   CLOCK

 

To set the clock using the CLOCK button, press the CLOCK UP/

DOWN.  The time will change by 1 minute. Press the APPLY to 

confirm the setting. The clock will keep the original time if the 

APPLY button is not pressed in 10 seconds.

20 .   APPLY

 

Save and Cancel the TIMER and CLOCK selection.

21 .   F/C

 

Press F/C to switch the remote and unit display temperature 

between Fahrenheit and Celsius.

22 .  LIGHT Button

 

Turns on and off the indoor display. To display only set 

temperature, press LIGHT button 10 times within 5 seconds. The 

indoor will beep 3 times when successful. To return to ambient 

temperature display, press LIGHT 10 times within 5 seconds 

again. Default is the indoor unit displaying ambient temperature. 

The set temperature will only display a for a few seconds after 

adjusting it with the remote.

23 .  RESET Button

 

If the remote control is not functioning properly, use a pen point or 

a similar object to depress this button to reset the remote. 

Manual Operation

• Use the POWER button only when the remote control is lost 

or damaged.

• Press the POWER button and the unit will beep once, 

indicating start of operation.

• The unit will run automatically in the following modes:

• While in Manual Operation, temperature and fan speed 

cannot be changed, nor will it operate in timer or DRY mode.

Inserting the Batteries

1. Remove the battery cover

2. Insert 2 AAA batteries as illustrated noting battery polarity

3. Reinstall the battery cover

NOTE:

• The distance from the remote control to the receiver should 

be less than 23 feet with no obstructions.

• If the remote control display is weak or the operating 

distance has diminished, the batteries may need to be 

replaced.

• Remote control malfunctions can sometimes be corrected 

by removing the batteries from the remote for a few 

minutes and then reinstalling them. 

• Remove the batteries from the remote control if the unit 

will not be in use for an extended period of time. If any 

segments of the display remain active after battery removal, 

press the reset button. 

Optimizing Performance

1. Close doors and windows during operation

2.  Do not block the air inlet or outlet

3.  Wipe the cabinet using a soft and dry cloth. For serious 

stains, use a nuetral detergent diluted with water. Wring the 

water out of the cloth before wiping down the unit. Then 

wipe off the detergent completely. 

Cleaning the Front Cover

1. Open the front cover by pulling it upward

2. Remove the Filter:

     Gently push up on the filter's center tab until it is released 

from the stopper, and remove the filter in a downward 

motion. 

3. Clean the filter

     Use a vacuum cleaner to remove dust, or wash the filter 

with water. After washing, dry the filter completely. 

4. Attach the filter

     Attach the filter so that the "FRONT" label is facing 

outward. Make sure that the filter is securly attached 

behind the holding tabs. If the filter is not attached 

correctly the unit may not achieve maximum efficiency. 

5. Close the front cover. 

Beep

emergency 

operation switch

Room 

Temperature

Designated 

Temperature

Timer 

Mode

Fan 

Speed

Operation 

Mode

Above 73°F

79°F

No

AUTO

COOL

Below 73°F

73°F

No

AUTO

HEAT

Summary of Contents for WJ26X27153

Page 1: ...ner s Manual Le manuel du propriétaire Manual del usuario YR HQ WJ26X27153 High Wall Duct Free System Système bi bloc sans conduits Sistema de Split sin Conducto 49 5000489 Rev 1 04 20 GEA F C APPLY SPEED ...

Page 2: ...2 49 5000489 Rev 1 ENGLISH ...

Page 3: ... model serial number information on this page To receive a 10 year compressor and parts warranty registration is required within 60 days of installation Thank you for purchasing this Haier product This installation manual will help you get the best performance from your new heat pump For future reference record the model and serial number located on the label on the side of your heat pump and the ...

Page 4: ...other appliance If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do These R410A heat pump systems require contractors and technicians use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R22 refrigerant only WARNING WARNING Keep batteries away from children This remote con...

Page 5: ...utton The TURBO function is used for speeding up the air flow to highest speed in heating and cooling mode The UI interface will display the TURBO icon Pressing the TURBO again or SPEED button will exit the Turbo function 7 QUIET Button The QUIET function is used for lowing the fan speed to the lowest speed The control will display the QUIET icon on the UI interface Pressing the QUIET button again...

Page 6: ... the eighth hour the unit will be back to the original setpoint This feature helps with achieving maximum efficiency and comfort while you sleep See the image below 1h Rises 1 2h 7h 8h In COOL DRY mode temp setting Unit stop SLEEP operation starts Rises 1 Decrease 1 Decrease 1 2 Heat Mode One hour after SLEEP mode starts the setting temperature will decrease 2 F After 2 hours later the setting tem...

Page 7: ...rt of operation The unit will run automatically in the following modes While in Manual Operation temperature and fan speed cannot be changed nor will it operate in timer or DRY mode Inserting the Batteries 1 Remove the battery cover 2 Insert 2 AAA batteries as illustrated noting battery polarity 3 Reinstall the battery cover NOTE The distance from the remote control to the receiver should be less ...

Page 8: ...shrinking due to temperature changes If the airflow is creating a loud noise during unit operation the air filter may be too dirty Odors The system circulates odors lingering in the airstream such as the smell of furniture paint and or cigarettes Mist or steam is blowing out During COOL or DRY mode the indoor unit may blow out mist or steam This is due to the sudden cooling of the indoor air In DR...

Page 9: ...49 5000489 Rev 1 9 ENGLISH ENGLISH For warranty detail please refer to installation manual Limited Warranty ...

Page 10: ...10 49 5000489 Rev 1 ENGLISH Notes ...

Page 11: ... de la pompe à chaleur et la date d achat Agrafez votre preuve d achat à ce manuel pour faciliter le service de la garantie en cas de besoin _______________________________________ Numéro de modèle _______________________________________ Numéro de série _______________________________________ Date d achat Pour enregistrer votre nouveau système sans conduit Haier allez sur la page haierductless com...

Page 12: ...proximité de cet appareil ou de tout autre Si vous vous débarrassez d un produit qui contient un frigorigène informez vous auprès de l organisme responsable d en disposer Ces systèmes de thermopompe R410A exigent que les entrepreneurs et les techniciens utilisent des outils des équipements et des normes de sécurité approuvés pour ce type de frigorigène N utilisez PAS un équipement certifié pour le...

Page 13: ...ration La fonction TURBO est utilisée pour accélérer la circulation d air à la vitesse la plus haute dans les modes chauffage et climatisation L interface utilisateur affichera le mot TURBO Presser TURBO de nouveau ou le bouton de vitesse du ventilateur vous fera quitter la fonction TURBO 7 Bouton QUIET silencieux La fonction QUIET fait passer le ventilateur à la vitesse la plus basse La télécomma...

Page 14: ... À la huitième heure l appareil retournera à la température de réglage initiale Cette fonction contribue à obtenir une efficacité et un confort optimaux pendant que vous dormez Voyez le schéma ci dessous 2 Mode HEAT Une heure après le début du mode SLEEP la température de réglage diminuera de 2 F Deux heures plus tard la température de réglage diminuera de 2 F supplémentaires Après cinq heures la ...

Page 15: ...squ à la dégager de la butée puis retirez le filtre dans un mouvement vers le bas 3 Nettoyer le filtre Utilisez un aspirateur pour enlever la poussière ou lavez le filtre avec de l eau Après le lavage séchez le filtre complètement 4 Fixez le filtre Fixez le filtre de façon que l étiquette FRONT avant soit face à l extérieur Assurez vous que le filtre est bien fixé derrière les languettes de retenu...

Page 16: ...température Un filtre trop sale peut être à l origine d une circulation d air bruyante durant le fonctionnement de l appareil Odeurs Le système fait circuler des odeurs qui persistent dans l air telles que peut en dégager meubles peinture ou cigarettes Production de brume ou de vapeur Dans les modes COOL climatisation ou DRY sec l unité intérieure peut souffler de la brume ou de la vapeur Cela est...

Page 17: ...49 5000489 Rev 1 17 FRANÇAIS Pour des renseignements détaillés sur la garantie veuillez vous reporter au manuel d installation Garantie limitée ...

Page 18: ...18 49 5000489 Rev 1 FRANÇAIS Remarques ...

Page 19: ...realizar un registro dentro de los 60 días desde el momento de la instalación Gracias por adquirir este producto de Haier Este manual del propietario le ayudará a lograr el mejor rendimiento de su nuevo acondicionador de aire Para referencia futura registre el modelo y número de serie ubicados en la etiqueta que se encuentra al costado de su bomba de calentamiento y la fecha de compra Abroche su c...

Page 20: ...stico Si se deshará de un producto antiguo con refrigerantes consulte a la compañía a cargo sobre cómo deshacerse del mismo Estos sistemas de bombas de calentamiento R410A requieren que los contratistas y técnicos usen herramientas equipos y estándares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado sólo para el refrigerante R22 ADVERTENCIA Mantenga las bat...

Page 21: ...quier otro botón para salir de esta función 6 Botón TURBO Turbo La función TURBO Turbo se usa para acelerar el flujo de aire hasta la velocidad más alta en el modo de calefacción y refrigeración La interface de usuario exhibirá el ícono TURBO Presionar TURBO nuevamente o el botón SPEED Velocidad hará que se salga de la función Turbo 7 Botón QUIET Modo Silencioso La función QUIET Modo Silencioso se...

Page 22: ...ión se reducirá 1 F 0 5 C En la octava hora la unidad volverá al punto de configuración original Esta función ayuda a lograr la máxima eficiencia y confort mientras usted duerme Lea la siguiente imagen 2 Modo HEAT Calor Una hora después de iniciado el modo SLEEP Inactividad la temperatura configurada disminuirá 2 F 2 horas más tarde la temperatura configurada disminuirá otros 2 F Luego de 5 horas ...

Page 23: ... y retire el filtro con un movimiento descendente 3 Limpie del Filtro Use una aspiradora para retirar el polvo o lave el filtro con agua Luego del lavado seque el filtro completamente 4 Adhiera el filtro Adhiera el filtro de modo que la etiqueta FRONTAL mire hacia afuera Asegúrese de que el filtro se encuentre adherido de forma segura detrás de las lengüetas de suspensión Si el filtro no se encuen...

Page 24: ...ura Si el flujo de aire está creando un ruido fuerte durante el funcionamiento de la unidad es posible que el filtro de aire también esté sucio Olores El sistema hizo circular olores que permanecieron en la circulación del aire tales como el olor de muebles pintura y o cigarrillos Se está emitiendo neblina o vapor Durante los modos COOL Frío o DRY Seco la unidad interna podrá emitir neblina o vapo...

Page 25: ...49 5000489 Rev 1 25 ESPAÑOL Para acceder a detalles de la garantía por favor consulte el manual de instalación Garantía Limitada ...

Page 26: ...26 49 5000489 Rev 1 ESPAÑOL Notas ...

Page 27: ...49 5000489 Rev 1 27 ESPAÑOL Funciones y Configuraciones del Control Remoto ...

Page 28: ... GARANTÍA IMPORTANT Do Not Return This Product To The Store If you have a problem with this product please call 1 877 337 3639 for the name and telephone number of the nearest authorized service center DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE IMPORTANT Ne pas Réexpédier ce Produit au Magasin En cas de problème avec ce produit veuillez composer le 1 877 337 3639 pour connaître le nom e...