TROUBLE SHOOTING
Long Wash Times
Incoming water should be at least 120 F
o
If the incoming water is below that level,
the heating element will be energized
during the wash and rinse cycle until the
temperature of the water reaches a
preset level, depending on the option.
The cycle will be extended for the period
of time that the heating element is on.
The heater will draw approximately
10.5 amps and can be checked for
operation with an amp probe.
Summary of Contents for UNDERCOUNTER DISHWASHER
Page 1: ...HAIER UNDERCOUNTER DISHWASHER Training Presentation ...
Page 2: ...CONTROL PANEL POWER BUTTON In to RUN OUT to STOP ...
Page 17: ...CONVECTION DRY FAN Testing 32 ohms resistance Test at quick disconnect ...
Page 18: ...CONVECTION DRY FAN Removal IMPORTANT Remove cover retaining screw ...
Page 22: ...CONTROL PANEL SERVICE Electronic Control Remove 2 Screws Pry PC Board off of posts ...
Page 24: ...CONTROL PANEL SERVICE Electronic Control Connections ...
Page 31: ...CONTROL PANEL SERVICE Power Switch Switch OUT OFF Switch IN ON ON Open Closed OFF Open Closed ...
Page 36: ...TANK OVERFILL Pump Motor ...
Page 37: ...FLOAT SAFETY SWITCH Remove Screw Float Body held in place with screws through bottom plate ...
Page 45: ...HEATING ELEMENT Be certain gasket is in place when replacing heater ...
Page 49: ...FILL VALVE SOLINOID Valve Body is Metric Thread U S adaptor provided on valve when unpacked ...
Page 54: ...PUMP AND MOTOR ASSEMBLY Motor wiring connector Motor capacitor ...
Page 57: ...UPPER WASH ONLY VALVE Ohmmeter test of the solenoid ...