Introduction
Domestic air conditioner
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the
installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks.
If a combustible gas leaks and remains around the unit, it can cause a fire.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not
installed properly, water can enter the room and wet the furniture and floor.
1.2.3 Inspection after Repair
Warning
Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet
all the way.
If the plug has dust or loose connection, it can cause an electrical shock or fire.
If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
Damaged cable and wires can cause an electrical shock, excessive heat generation or fire.
Warning
Do not use a joined power cable or extension cable, or share the same power outlet with other electrical
appliances since it can cause an electrical shock, excessive heat generation or fire.
5
Summary of Contents for JS035-D2
Page 12: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 EEV EEV ...
Page 14: ...Printed circuit board connector wiring diagram 12 Domestic air conditioner PCB 1 ...
Page 46: ......
Page 51: ...three 6 Removal Procedure 4 Domestic Air Conditioner Remove the casing 1 2 3 ...
Page 55: ...Removal Procedure 8 Domestic Air Conditioner motor cover motor cover ...
Page 56: ...Removal Procedure 9 Domestic Air Conditioner ...