19
18
Troubleshooting
Care and cleaning
Water inlet valve and inlet valve filter
To prevent blockage of water supply by foreign substances,
clean inlet valve filter regularly.
Period of disuse
If the appliance is left idle for a longer period, pull out
the electrical plug (1) and turn off water supply (2).
Open the door to prevent formation of moisture and
odours. Let door open while not used.
Before next usage check carefully power cord, water inlet
and drain hose. Make sure everything is properly installed
and without leackage.
Display code
Code Cause
Solution
Auto Automatic load detection. Wait until programme cycle time
is displayed.
1:25
Remaining wash cycle time.
Refer to additional symbol.
19:30
Remaining wash cycle time.
End is likely delayed - refer to symbol.
Lock
Door is locked.
Wait, operational door locking.
End
End of wash cycle.
E1
Drainage error, water is not
Clean pump filter.
fully drained within 6 minutes.
Check drain hose for blockage
and proper installation.
E2
Lock - error.
Shut the door properly,
F3
Temperature sensor - error.
Contact the After sales service.
E4
Water level not reached after 8 minutes.
Make sure that tap is fully opened
Drain hose is self-syphoning.
and water pressure is normal.
Check drain hose installation.
F4
Heating error (Appears at the end of a cycle). Contact the After sales service.
F7
Motor - error.
Contact the After sales service.
E8
Water protective level - error.
Auto released otherwise contact the
after sales service.
Fb
Water overflow .
Close tap immediately.
Contact the After sales service.
FA
Water level sensor error.
Contact the After sales service.
FC
Electronic control - error.
Contact the After sales service.
Unb
Unbalanced load - error.
Cut power supply. Check and
balance laundry load. Try to run a
spinning programme
Warning!
Code
Fb
: Water-overflow protection is placed on deepest part of appliance. In case of leacka -
ge all functions will be shut down automatically except drain pump which will be activated for
safety reasons.