Troubleshooting
18
S/N
Possible
Malfunctions
Possible
causes
Checking Steps
Instrument
Solutions
1. Check whether the tap is
open.
Eyeballing
If normal, go on with the next
step.
2. Check whether the water
pressure is too low.
Eyeballing
If normal, go on with the next
step.
3. Check whether the
electromagnetic valve is well
linked.
Eyeballing
If normal, go on with the next
step.
4. Check whether the
pressure switch is well linked.
Eyeballing
If normal, go on with the next
step.
5. Check whether the
pressure switch hose leaks
gas or not.
Eyeballing
Blowing
If normal, go on with the next
step.
6. Check whether the
electromagnetic valve is
damaged.
Check by
hand
Eyeballing
Multimeter
If normal, go on with the next
step.
7. Check whether the
pressure switch is damaged.
Eyeballing
Multimeter
If normal, go on with the next
step.
9 Err5
Alarm
The water
switch does
not move
within 8
minutes.
8. Check whether the relevant
wiring harness is broken.
Eyeballing
Multimeter
If normal, change power
drive board.
1. Check whether the motor is
well linked.
Eyeballing
If normal, go on with the next
step.
2. Check whether the motor is
damaged ( or over-heated ).
Eyeballing
Multimeter
If normal, go on with the next
step.
10
Err6, Err7,
FErr Alarm
The motor is
broken.
3. Check whether the relevant
wiring harness is broken.
Eyeballing
Multimeter
If normal, change power
drive board.
1. Check whether the
drainage pump is well linked.
Eyeballing
If normal, go on with the next
step.
2. Check whether the
drainage pump is damaged
(short circuit inside).
Eyeballing
Multimeter
If normal, go on with the next
step.
3. Check whether the
pressure switch is well linked.
Eyeballing
If normal, go on with the next
step.
4. Check whether the
pressure switch is damaged.
Eyeballing
Multimeter
If normal, go on with the next
step.
5. Check whether the
pressure switch hose leaks
gas or not.
Eyeballing
Blowing
If normal, go on with the next
step.
11 Err8
Alarm
The water
level is over
the
protecting
water level.
6. Check whether the relevant
wiring harness is broken.
Eyeballing
Multimeter
If normal, change power
drive board.
Summary of Contents for HT1006TXVE
Page 6: ...Safety caution 6 ...
Page 7: ...Safety caution 7 ...
Page 8: ...Safety caution 8 ...
Page 9: ...lnstallation 9 lnstallation 9 ...
Page 10: ...Installation 10 ...
Page 11: ...Functions 11 ...
Page 12: ...Functions 12 ...
Page 13: ...Function schedule 13 ...
Page 14: ...Function schedule 14 Function schedule 14 ...
Page 15: ...Troubleshooting 15 ...
Page 19: ...Wiring circuit 19 ...
Page 20: ...Exploded view and list of parts 20 Exploded view 78 77 ...