Indoor unit

Fix to side bar and lintel a mounting bar, Which is separately sold, and then

ƽ

fasten the plate to the fixed mounting bar.

Refer to the previous article, “ When the mounting plate is

ƽ

position of wall hole.

Make a hole of 60 mm in diameter, slightly descending to outside the wall.

ƽ

Install piping hole cover and seal it off with putty after installation

ƽ

When the mounting plate is first fixed

1. Carry out, based on the neighboring pillars or lintels, a 

to be fixed against the wall, then temporarily fasten the plate with one steel nail.

2. Make sure once more the proper level of the plate, by hanging a thread with a 

weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.

3. Find the wall hole location A using a measuring tape

A=145mm

B= 60mm

30mm

When  the mounting plate is fixed side bar and lintel

Fitting of the Mounting Plate and Positioning of the wall Hole

Lid for right
piping

Lid for under piping pipe

Fix with adhesive tape

Lid for left piping

Indoor/outdoor electric cable and drain hose must be bound with refrigerant

ƽ

piping by protecting tape.

[ Other direction piping  ]

Cut away, with a nipper, the lid for piping according to the piping direction and

ƽ

then bend the pipe according to theposition of wall hole. When bending, be

careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable,

ƽ

and then pull out the

connected to the heat insulation of connecting part specially.

proper leveling for the plate

first fixed “, for the

Making a Hole on the Wall and Fitting the Piping Hole Cover

Drawing of pipe

Installation of the Indoor Unit

[ Rear piping  ]

Draw pipes and the drain hose, then fasten them with the adhesive tape

ƽ

[ Left

·

Left-rear piping ]

In case of left side piping, cut away, with a nipper, the lid for left piping.

ƽ

In case of left-rear piping, bend the pipes according to the piping direction to

ƽ

the mark of hole for left-rear piping which is marked on heat insulation materials.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside  of  indoor unit, and pull it

out on the front side, then connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

Cover the connection part with heat insulation materials closely, and make sure

fixing with adhesive tape

Fixing the indoor unit body

Hang surely the unit body onto the upper notches of the

ƽ

mounting plate. Move the body from side to side to verify its
secure fixing.

In order to fix the body onto the mounting plate,hold up

ƽ

the body aslant from the underside and then put it down
perpendicularly.

Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Remove terminal cover at right bottom corner of indoor unit, then take

ƽ

 off wiring cover by removing its screws.

1. Insert from outside the room cable into left side  of  the wall

hole, in which the pipe has already existed.

2. Pull out the cable on the front side, and connect the cable

making a loop.

Insert the cable from the back

ƽ

side of the unit, then pull it out on the front side.

Loosen the screws and insert

ƽ

the cable ends fully into terminal block, then

tighten the screws.

Pull the cable slightly to

ƽ

make sure the cables have been properly inserted and

tightened.

mounting plate

When connecting the cable after installing the indoor unit

When connecting the cable before installing the indoor unit

When you unload the indoor unit,please use 

then lift the bottom of the body outward
slightly and lift the unit aslant until it
leaves the mounting plate. 

agraffe

mounting plate

Unloading of indoor unit body

ƽ

your hand to arise the body to leave agraffe,

Remote controller (1)

R-03 dry battery (2)

Mounting plate (1)

Drain hose (1)

Ø4X25 Screw (4)

Plastic cap (4)

Drain-elbow (1)

Cushion (4)

Pipe supporting plate (1)

Accessory parts

Liquid pipe (Ø)

6.35mm(1/4”)

Gas pipe (Ø)

9.52mm(3/8”)

NOTE

˖

The thickness  of  the pipe must be 0.8mm  at  least.

Selection of pipe

2

Indoor side

Outdoor side

Ø60mm

Wall hole

Thickness of wall

(Section of wall hole)

 Piping hole pipe

G

Heat insulation
material

Drain hose

Piping

Pipe supporting
plate

Indoor/outdoor electric cable

A=145mm

B=

60mm

Ø

30mm

A=135mm

B=

60mm

Ø

30mm

A=135mm

B=

60mm

Ø

30mm