background image

22

Maintenance

1.Open the lnlet Grille

2.Detach the standard air filter

3.Attach new Air Purifying Filter

4.Attach the standard air filter

(Necessary installation)

5.Close the Inlet Grille

Close the Grille surely

Open the inlet grille by pushing each ends of
the inlet grille upward.(use thumbs to push
up)

Slide the knob slightly upward to release the
filter, then withdraw it.

Put air purifying filter appliances into the 
right and left filter frames.

Detach old Air Purifying Filter

Replancement of Air Purifying Filter

Note:
(1) the bacteria-killing mediums placed on
     the left side. the multi-lights touching ntermediary 
     is placed on the right side.
(2)the green aspect of the bacteria-killing medium
   air purifying filter will face outside,the white 
    aspect will face to the machine.

NOTE:

The photocatalyst air purifying filter and the 

bacteria-killing medium air purifying filter 

will be used based on real situation.

The photocatalyst air purifying filter will be solarized in fixed time. In normal family, 
it will be solarized every 6 months. The solarization time will last no less than 8 hours 
under the state of abundant sun.

The bacteria-killing medium air purifying filter is available for a long time and neednít 
to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb 
the dusts covering the purifying filter lest the covering dusts effect the function of the 
bacteria-killing medium air purifying filter. (It is strictly prohibited for the bacteria-killing 
medium air purifying filter to be washed)

Summary of Contents for HSU-18CV03(T3)

Page 1: ...No 0010556977 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner HSU 18CV03 T3 HSU 24CV03 T3...

Page 2: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Page 3: ...ne is adaptive in following situation 10 The power plug and connecting cable must have acquired the local attestation 2 If the power supply cord is damaged it must be replaced by the manufacturer or i...

Page 4: ...e Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a ina...

Page 5: ...ially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occ...

Page 6: ...d Inlet Air Purifying Filter Vertical flap adjust up and down air flow Don t adjust it manually Horizontal louver Air filter inside Inlet grille Power plug adjust left and right air flow inside Outlet...

Page 7: ...w display Remote controller to display the TEMP setting 22 TEMP display 23 TIMER OFF display 24 CLOCK display 25 TEMP button Used to select fan speed LOW MED HI AUTO 26 FAN button Used to set the heal...

Page 8: ...e as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is...

Page 9: ...no TiO2 on the multi lights touching intermediary and the degerming effect is highly efficient and lasting Note when the function is running don t open the inlet grille About UV light degerming functi...

Page 10: ...roller Then Select Auto operation AUTO COOL DRY FAN HEAT Press FAN button For each press fan speed changes as follows Remote controller Press TEMP button Every time the button is pressed temp setting...

Page 11: ...it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp settin...

Page 12: ...n is pressed temp setting increase 1o C if kept depressed it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desir...

Page 13: ...Fan speed selection 4 Unit stop About FAN operation In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is dis...

Page 14: ...ease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops AUTO LOW MED HI AUTO COOL D...

Page 15: ...The vertical flap will swing according to the above positions HEAT AUTO 1 Status display of air sending Horizontal louvers Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 3 Left and right air flow dir...

Page 16: ...tting so that room temperature won t be too Iow for your sleep Remote Controller SLEEP operation starts SLEEP operation stops SLEEP operation starts SLEEP operation stops Approx 6hrs 1 hr 1 hr 1 hr 3...

Page 17: ...ressed display changes as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every...

Page 18: ...OFF will flash 3 Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting...

Page 19: ...tting the health airflow function the position of inlet and outlet grills is fixed 2 In heating it is better to select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using...

Page 20: ...in the test operation when the room temperature is below 16 O C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound t...

Page 21: ...tion If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Proper t...

Page 22: ...etely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the control...

Page 23: ...t of the bacteria killing medium air purifying filter will face outside the white aspect will face to the machine NOTE The photocatalyst air purifying filter and the bacteria killing medium air purify...

Page 24: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Page 25: ...e plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may ca...

Page 26: ...ve elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a sw...

Reviews: