HSU-09LEK03

/

(DB)

HSU-12LEK03

/

(DB)

Indoor unit

Outdoor unit

HSU-108CH09

HSU-138CH09

1

(

N)

2(

L

)

3(C)

3

(

C

)

2

(

L

)

1

(

N

)

connecting wiring:

Power cable:

-mod 09-12:

3G1.0mm

-mod 09-12:

3G1.5mm   +1X0.75mm

Power cable:

3G1.0mm

5G1.0mm

Indoor unit

Outdoor unit

HSU-09LEK03

Indoor unit

Outdoor unit

HSU-12LEK03

HSU-07HEK03

HSU-12HEK03

HSU-09LEK13

HSU-12LEK13

HSU-07LEK03

HSU-09HEK03

HSU-12LEK13-M

connecting wiring:
-mod 07-12:    3G1.0mm

Power cable:
-mod 07-12:     3G1.0mm

)

2(N)

1(L

Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Remove terminal cover at right bottom corner of indoor unit, then

take off wiring cover by removing its screws.

When connecting the cable after installing the indoor unit

1. Insert from outside the room cable into left side of the wall hole, in which

    the pipe has already existed.

2. Pull out the cable on the front side, and connect the cable making a loop.

Indoor unit

1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar

   qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).

2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.

3. The wiring method should be in line with the local wiring standard.

4. After installation, the power plug should be easily reached.

When connecting the cable before installing the indoor unit

Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.

Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring

       is not correct, proper operation can not be carried out and will cause defect.

5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the

    distance between its two contacts should be not less than 3mm.

 If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.

Power cable:

3G2.5mm

4G0.75mm

1

2

3

4

5

Indoor unit

Outdoor unit

HSU-24LEK13

3G2.0mm

Power cable:

HSU-18LEK13

Indoor unit

Outdoor unit

4

3

3G1.5mm

HSU-18HEK03

3G1.0mm

Power cable:

Indoor unit

Outdoor unit

4

3

3G1.0mm

N

L

1

2

3

4

5

POWER

SUPPLY

BL

BR

Y/G

Indoor unit

Outdoor unit

6G0.75mm

Power cable:

3G2.5mm

HSU-24HEK03

Power cable:

3G1.5mm

4G1.5mm

Indoor unit

Outdoor unit

HSU-18LEK03/(DB)

4

3